مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,845
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A MONTE CARLO SIMULATION OF PHOTON BEAM GENERATED BY A LINEAR ACCELERATOR

Author(s)

BAHREYNI TOUSI S.M.T. | MOUMENNEZHAD M. | SABERI H. | BAHREYNI TOUSI SEYED MOHAMMAD HOSSEIN | HASHEMIAN H. | SALEK R. | MIRI H. | Issue Writer Certificate 

Pages

  3-12

Abstract

 Introduction: MONTE CARLO SIMULATION is the most accurate method of simulating radiation transport and predicting doses at different points of interest in radiotherapy. A great advantage of the MONTE CARLO method compared to the deterministic methods is the ability to deal accurately with any complex geometry. Its disadvantage is the extremely long computing time required to obtain a dose distribution with good statistical accuracy.Materials and Methods: The MCNP-4C MONTE CARLO code was used to simulate a 9 MV PHOTON BEAM from a Neptun 10PC LINEAR ACCELERATOR. The accelerator was modeled as a complete unit consisting of a target, exit window, initial collimator, primary collimator, flattening filter, monitor chamber and secondary collimator. The geometrical details and the composition of each component was either obtained from the manufacturer or was directly measured. The SIMULATION of the source was performed in a two step process. Initially, the electron source was defined. Secondly, the bremsstrahlung energy spectra and the fluence distribution at the scoring planes were used to define the photon source. The simulated electron beam energy followed a Gaussian distribution, with FWHM equal to 12% in nominal energy. The used intensity distribution of the electron beam also followed a Gaussian distribution with a FWHM equal to 0.34 cm. To compute the PHOTON BEAM data a 50 x 50 x 40 cm3 water phantom located at SSD = 100 cm was simulated. The depth dose and the dose profile curves were calculated for four different field sizes (5x5, 10x10, 20x20 and 30x30 cm2) and compared against the measured values. The low-energy cut-off for the photons and electrons was 10 and 500 KeV, respectively. The measurements were carried out by using a Scanditronix dose scanning system and a 0.12 cm3 RK ionization chamber.Results: To verify the simulated model, the calculated MONTE CARLO dose data were compared against the corresponding measured values. The energy spectra and the angular distribution of the x-ray beam generated by the Neptun 10PC linac was examined. The result showed an efficiency of about 73% for the production of bermsstrahlung photon by the target. The agreement between the calculated and the measured depth dose and the dose profile was generally better than 2% for all the fields.Discussion and Conclusion: The SIMULATION of the Neptun 10PC linac performed in this work is capable of computing the depth dose data and the beam profiles in water phantom for all the predefined fields including 5x5, 10x10, 20x20 and 30x30 cm2. Therefore, it can be concluded that MCNP-4C is a suitable tool for the dose calculation in radiotherapy. The simulated linac machine and the resulting data can be used to predict the dose distribution in all complex fields.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    BAHREYNI TOUSI, S.M.T., MOUMENNEZHAD, M., SABERI, H., BAHREYNI TOUSI, SEYED MOHAMMAD HOSSEIN, HASHEMIAN, H., SALEK, R., & MIRI, H.. (2005). A MONTE CARLO SIMULATION OF PHOTON BEAM GENERATED BY A LINEAR ACCELERATOR. IRANIAN JOURNAL OF MEDICAL PHYSICS, 2(7), 3-12. SID. https://sid.ir/paper/96894/en

    Vancouver: Copy

    BAHREYNI TOUSI S.M.T., MOUMENNEZHAD M., SABERI H., BAHREYNI TOUSI SEYED MOHAMMAD HOSSEIN, HASHEMIAN H., SALEK R., MIRI H.. A MONTE CARLO SIMULATION OF PHOTON BEAM GENERATED BY A LINEAR ACCELERATOR. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2005;2(7):3-12. Available from: https://sid.ir/paper/96894/en

    IEEE: Copy

    S.M.T. BAHREYNI TOUSI, M. MOUMENNEZHAD, H. SABERI, SEYED MOHAMMAD HOSSEIN BAHREYNI TOUSI, H. HASHEMIAN, R. SALEK, and H. MIRI, “A MONTE CARLO SIMULATION OF PHOTON BEAM GENERATED BY A LINEAR ACCELERATOR,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 2, no. 7, pp. 3–12, 2005, [Online]. Available: https://sid.ir/paper/96894/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button