مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

843
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DETERMINATION OF THE RADIAL DOSE FUNCTION, ANISOTROPY FUNCTION AND ANISOTROPY CONSTANT FOR THE FIRST 103PD SEED MANUFACTURED AT AMIRS USING TLD-100

Pages

  17-24

Abstract

 Introduction: BRACHYTHERAPY sources of 103Pd with low photon energies are being used for interstitial implants in prostate tumors. DOSIMETRIC PARAMETERS of these sources such as air kerma strength, dose rate constant, geometry function, radial dose function and anisotropy function should be calculated and measured accurately according to the recommendations of American Association of Physicists in Medicine (AAPM) addressed in TG-43U1 PROTOCOL. The first type of 103Pd BRACHYTHERAPY seeds have been manufactured at Agricultural, Medical and Industrial Research Institute (AMIRI)- Atomic Energy Organization of Iran. Therefore, it is necessary to determine the TG-43U1 DOSIMETRIC PARAMETERS before clinical implementation.Materials and Methods: In this work, the radial dose function, anisotropy function and anisotropy constant for the first 103Pd seed manufactured at AMIRS have been determined using TLD-100 dosimeters. The TLD having dimensions of 3.1 ×3.1×0.9 mm3 were calibrated using 60Co radiation field. The TLD measurements were preformed in 30×30×30 cm3 Perspex phantoms in order to provide full scattering conditions. In this work, two phantoms were designed. The first phantom was used for the experimental determination of radial dose function and the second one was used for the experimental determination of anisotropy function. Dose distribution around the source was measured by TLD-100 dosimeters using RMKL KFKI reader. Results: The radial dose function, anisotropy function and anisotropy constant of the first AMIRI 103Pdwereseed determined according to TG-43U1 recommendations. The obtained result was in good agreement with the results published by Meigooni et al for Best double-walled model 103Pd source.Discussion and Conclusion: The spatial dose distribution around the source and DOSIMETRIC PARAMETERS determined in this work showed that in dosimetry point of view, the new model 103Pd source manufactured at AMIRI is suitable for use in brachy therapy of prostate cancer.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    RAEIS ALI, GH.R., GHASEMI GHONCHEHNAZI, M., SHOKRANI, P., SADEGHI, MAHDI, SHAHVAR, A., & ARBABI, K.. (2007). DETERMINATION OF THE RADIAL DOSE FUNCTION, ANISOTROPY FUNCTION AND ANISOTROPY CONSTANT FOR THE FIRST 103PD SEED MANUFACTURED AT AMIRS USING TLD-100. IRANIAN JOURNAL OF MEDICAL PHYSICS, 3(13), 17-24. SID. https://sid.ir/paper/96927/en

    Vancouver: Copy

    RAEIS ALI GH.R., GHASEMI GHONCHEHNAZI M., SHOKRANI P., SADEGHI MAHDI, SHAHVAR A., ARBABI K.. DETERMINATION OF THE RADIAL DOSE FUNCTION, ANISOTROPY FUNCTION AND ANISOTROPY CONSTANT FOR THE FIRST 103PD SEED MANUFACTURED AT AMIRS USING TLD-100. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2007;3(13):17-24. Available from: https://sid.ir/paper/96927/en

    IEEE: Copy

    GH.R. RAEIS ALI, M. GHASEMI GHONCHEHNAZI, P. SHOKRANI, MAHDI SADEGHI, A. SHAHVAR, and K. ARBABI, “DETERMINATION OF THE RADIAL DOSE FUNCTION, ANISOTROPY FUNCTION AND ANISOTROPY CONSTANT FOR THE FIRST 103PD SEED MANUFACTURED AT AMIRS USING TLD-100,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 3, no. 13, pp. 17–24, 2007, [Online]. Available: https://sid.ir/paper/96927/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button