مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

838
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

FABRICATION OF FREE AIR WELL TYPE IONIZATION CHAMBER AND CALCULATIONAL ASSESSMENT AND MEASUREMENT OF ITS OPERATIONAL CHARACTERISTICS

Pages

  1-10

Abstract

 Introduction: Well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. The chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. For the measurements, the brachytherapy sources are transferred to the middle of the tube.Materials and Methods: For designing the WEN TYPE CHAMBER, the measurement principals of WEN TYPE CHAMBERs were considered and MCNP-4C code as a calculation tool was used. The designed chamber was simulated and the response of the chamber was evaluated. In this investigation, the chamber operational parameters such as operating voltage, leakage current, reproducibility, reference measuring point, recombination and polarization factors as well as response stability for 137Cs, 57CO and 241Am sources were studied.Results: The chamber leakage currents at the operating voltage in comparison to the chamber response for the measurement of the above mentioned sources were negligible. The responses of the fabricated chamber for these sources are reproducible and its reference measurement position for these sources was obtained at 6 cm from the bottom of the chamber. The recombination factor for the well type chamber was negligible and the polarization factor is close to 1. Therefore, these two factors were not considered in the measurements. The reproducibility of the measurements in different intervals shows the stability of the chamber response for each source. Also the results of the chamber current measurement in term of source strength were compared to the response of the simulated chamber for different source positions and energy ranges of the used sources.Discussion and Conclusion: The results show that the measurement of the reference positions for each source in the simulated and fabricated chamber is quite in a good agreement. Regarding the reliable operational properties of the fabricated chamber, this chamber can be used to determine the activities of brachytherapy sources in which the energy ranges are greater than 50 KeV.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ARBABI, KOROUSH, RAISALI, GHOLAMREZA, DEHGHANI MOGHADAM, MASOOMEH, GHAFOORI, MOSTAFA, SHAHVAR, ARJANG, & HAMIDI, SAID. (2008). FABRICATION OF FREE AIR WELL TYPE IONIZATION CHAMBER AND CALCULATIONAL ASSESSMENT AND MEASUREMENT OF ITS OPERATIONAL CHARACTERISTICS. IRANIAN JOURNAL OF MEDICAL PHYSICS, 4(2 (16-17)), 1-10. SID. https://sid.ir/paper/96999/en

    Vancouver: Copy

    ARBABI KOROUSH, RAISALI GHOLAMREZA, DEHGHANI MOGHADAM MASOOMEH, GHAFOORI MOSTAFA, SHAHVAR ARJANG, HAMIDI SAID. FABRICATION OF FREE AIR WELL TYPE IONIZATION CHAMBER AND CALCULATIONAL ASSESSMENT AND MEASUREMENT OF ITS OPERATIONAL CHARACTERISTICS. IRANIAN JOURNAL OF MEDICAL PHYSICS[Internet]. 2008;4(2 (16-17)):1-10. Available from: https://sid.ir/paper/96999/en

    IEEE: Copy

    KOROUSH ARBABI, GHOLAMREZA RAISALI, MASOOMEH DEHGHANI MOGHADAM, MOSTAFA GHAFOORI, ARJANG SHAHVAR, and SAID HAMIDI, “FABRICATION OF FREE AIR WELL TYPE IONIZATION CHAMBER AND CALCULATIONAL ASSESSMENT AND MEASUREMENT OF ITS OPERATIONAL CHARACTERISTICS,” IRANIAN JOURNAL OF MEDICAL PHYSICS, vol. 4, no. 2 (16-17), pp. 1–10, 2008, [Online]. Available: https://sid.ir/paper/96999/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top