چکیده: 

Background: The (DVH) is the most used radiotherapy formulation. (DVH) plays a fundamental role in determining DOSE constraints and side effects. VOLUME also plays the main role in calculating (DVH). In prostate treatment, there is no comprehensive consensus on determining the association between bladder VOLUME (BV) and side effects. Our aim is to investigate the reproducibility of bladder (DVH) ((DVH)B). D50%BV (DOSE received by 50% of BV) is used to analysis (DVH)B. Materials and Methods: We contoured the bladder of 467 daily MVCT images of fifteen prostate cancer patients who underwent tomotherapy. Using R software 4.2.3, the correlation between the bladder center of mass (XCM, YCM, ZCM), BV with D50%BV were modeled by the mixed model. Two prediction models were presented for D50%BV, the first model was based on BV and (XCM, YCM, ZCM), the second model was based on BV. Results: Statistical analyses revealed that independent factors YCM, ZCM, and BV have a significant influence on the response variable D50%BV. According to mixed model, YCM has a positive correlation with D50%BV, while ZCM or BV has a negative correlation. XCM does not significantly affect D50%BV. Akaike Information Criterion (AIC) index indicated that first model has a higher goodness of fit than second one. Conclusion: Our findings demonstrate that bladder location also affects D50%BV, in addition to BV. It can be concluded that (DVH)B is not always repeatable as a scientific claim.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 7

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1391
  • دوره: 

    14
  • شماره: 

    4 (پی در پی 67)
  • صفحات: 

    45-52
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    2100
  • دانلود: 

    220
چکیده: 

سابقه و هدف: سرطان پستان یکی از شایعترین سرطانهای زنان در جهان است که بعد از ماستکتومی، رادیوتراپی بهترین گزینه درمانی آن است. ایجاد توزیع دز یکنواخت در تمام حجم درمان یکی از مهمترین اهداف رادیوتراپی می باشد. هدف از این تحقیق ارزیابی زوایای دیواره قفسه سینه با خطوط مرجع (عمودی و افقی)، برای انتخاب زاویه بهینه فیلتر وج در رادیوتراپی پستان ماستکتومی شده، می باشد. مواد و روشها: در این مطالعه 140 بیمار که پس از جراحی ماستکتومی نیاز به رادیوتراپی داشتند، مورد بررسی قرار گرفتند. بیماران با سیستم طراحی درمان دو بعدی ALFARD یا طراحی درمان سه بعدی CorePLAN درمان شدند. هیستوگرام دز - حجم برای هر مورد برای زوایای مختلف وج و همچنین میدان باز استخراج شد. با آنالیز و مقایسه آنها زاویه وج بهینه بدست آمد. زاویه دیواره قفسه سینه با خطوط مرجع با نرم افزار GET DATA اندازه گیری شد. سپس زاویه قفسه سینه و زاویه بهینه وج برای بدست آوردن رابطه بین آنها، مقایسه شد. یافته ها: زاویه وج بهینه برای درمان هر بیمار تابعی از زوایای قفسه سینه بود. در تمام بیماران با استفاده از فیلتر وج دز یکنواخت تری برای درمان فراهم شد و نتایج حاصل از تعیین زاویه وج بهینه با روش جدید اندازه گیری زوایای قفسه سینه و روش تهیه هیستوگرام دز _ حجم به عنوان روش استاندارد همخوانی داشت. نتیجه گیری: نتایج این تحقیق نشان داد که زاویه دیواره قفسه سینه در بیماران ماستکتومی شده روش جدیدی برای انتخاب زاویه وج بهینه درمان است. همچنین این روش نسبت به روش تهیه هیستوگرام دز – حجم دارای فرآیند زمانی کوتاه تری می باشد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 2100

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 220 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

Inal A. | Duman e. | Ozkan E.E.

اطلاعات دوره: 
  • سال: 

    2020
  • دوره: 

    18
  • شماره: 

    3
  • صفحات: 

    477-486
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    150
  • دانلود: 

    0
چکیده: 

Background: We aimed to investigate the accordance of Critical Organ Scoring Index (COSI), Conformity Index (CI) and Normal Tissue Complication Probability (NTCP) parameters with DOSE VOLUME HISTOGRAMs ((DVH)) used for evaluation of 3 different pelvic radiotherapy plans. Materials and Methods: Ten gynecologic carcinoma patients who underwent adjuvant radiotherapy were enrolled in this study. Treatment plans were created with conformal treatment planning (3DCRT) and intensity modulated radiation therapy (IMRT) to a total DOSE of 50. 4 Gy in 28 fractions. Initially, VOLUME related DOSE evaluation was done via (DVH). Subsequently, HI, CI, COSI and NTCP for selected normal tissues were calculated for each plan and compared with (DVH) parameters. Finally, a graphical demonstration was evaluated to see if the results were in accordance with (DVH). Results: CI results were statistically significant in favor of IMRT (p<0. 001). Rectum V40Gy decreased with 9IMRT compared to 3DCRT and 7IMRT (p=0. 013 and p=0. 013). V40Gy for bladder was also lower with 9IMRT compared with 3DCRT and 7IMRT (p=0. 005 and p=0. 012). COSI calculations revealed better small intestine protection in IMRT plans similar with (DVH) (p=0. 005 and p=0. 022). Femoral heads were better protected with IMRT plans were better compared to 3DCRT in NTCP calculations (p=0. 002). Normal tissue protection was worst with 3DCRT via both (DVH) and COSI evaluations (p=0. 001 and p<0. 001 respectively). Conclusion: Using the indexes in this study to decide the most appropriate plan among multiple treatment plans in gynecologic cancer patients will be timesaving and easier in comparison with evaluating the (DVH) of every alternative plan.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 150

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1402
  • دوره: 

    41
  • شماره: 

    716
  • صفحات: 

    270-276
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    59
  • دانلود: 

    8
چکیده: 

مقاله پژوهشیمقدمه: سرطان کولورکتال، شایع ترین سرطان دستگاه گوارش و همچنین چهارمین دلیل مرگ در جهان است. این مطالعه، با هدف بررسی و مقایسه ی تفاوت های دزیمتریک در پرتودرمانی سرطان رکتوم در دو موقعیت طاقباز و دمر انجام گردید.روش ها: در یک مطالعه ی مقطعی در بیمارستان میلاد شهر اصفهان، اطلاعات سی تی اسکن 30 بیمار کاندید پرتودرمانی مبتلا به سرطان رکتوم به نرم افزار طراحی درمان ارسال شد. حجم هدف (Planning target VOLUME) PTV و اعضای در معرض خطر شامل باول بگ (حجم روده) و مثانه توسط رادیوانکولوژیست کانتور گردید. طراحی درمان پرتودرمانی تطبیقی سه بعدی (Three-dimensional conformal radiotherapy)  3D_CRTبا استفاده از دو روش 3 و 4 فیلد و انرژی 18 مگا ولت طراحی شد. در آخر، با استفاده از منحنی توزیع دز-حجم (DOSE- VOLUME HISTOGRAM) (DVH) متغیرهای دزیمتری حجم هدف و اندام های در معرض خطر استخراج و با یکدیگر مقایسه گردید.یافته ها: میانگین دز دریافتی باول بگ و مثانه در موقعیت دمر در روش 3 فیلد به طور معنی داری کمتر از سایر روش های مورد مطالعه بود. علاوه بر این موقعیت 3 فیلد طاقباز دز بالاتری را نسبت به 3 فیلد دمر به اندام های در معرض خطر می رساند. با این حال اندام ها در چهار فیلد موقعیت طاقباز در مقایسه با سایر فیلدها دز بالاتری را دریافت خواهند کرد.نتیجه گیری: در پرتودرمانی سرطان رکتوم، به دلیل بهبود پوشش حجم هدف و توزیع دز بهتر استفاده از طراحی درمان با روش 3 فیلد در موقعیت دمر پیشنهاد می شود.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 59

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 8 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1398
  • دوره: 

    37
  • شماره: 

    543
  • صفحات: 

    1080-1087
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    643
  • دانلود: 

    148
چکیده: 

مقدمه: پرتودرمانی با شدت مدوله شده (Intensity-modulated radiation therapy یا IMRT) یکی از بهترین روش ها: در درمان مننژیومای عصب بینایی (Optic nerve sheath meningioma یا ONSM) همراه با کنترل رشد تومور وتثبیت بینایی می باشد. در این مطالعه، تکنیک های مختلف IMRT از دیدگاه میزان افت دز در بعد از مرزهای هدف درمان جهت دستیابی به تکنیک بهینه مورد بررسی قرار گرفتند. روش ها: فرایند بهینه سازی 3 تکنیک IMRT با استفاده از 3، 5 و 7 فیلد با فوتون 6 مگاولت برای 15 نفر از بیماران مبتلا به مننژیومای عصب بینایی با استفاده از سیستم طراحی درمان Panther Prowess انجام شد. برای ارزیابی طرح های درمان علاوه بر اطلاعات استخراج شده از هیستوگرام دز-حجم (DOSE-VOLUME HISTOGRAM یا (DVH)) و محاسبه ی شاخص های ارزیابی پوشش هدف، شاخص شیب دز (یا DGI) تفاضلی و تجمعی در هر سه تکنیک محاسبه و مقایسه شد. یافته ها: دز بیشینه و دز میانگین رسیده به تومور با افزایش تعداد فیلدهای IMRT افزایش یافت. مقادیر شاخص یکنواختی (Uniformity index یا UI) و همگنی (Homogeneity index یا HI) بین تکنیک 3 بیم و 7 بیم اختلاف معنی داری نشان داد و شاخص انطباق (Conformity index یا CI) در تکنیک 7 بیم بسیار نزدیک به مقدار ایده آل (99/0) به دست آمد. شاخص شیب دز تفاضلی (Difference DOSE gradient index یا dDGI) در بین سه تکنیک اختلاف ناچیزی با هم داشت و تنها در سطح ایزودز 45 درصد اختلاف معنی داری بین تکنیک 5 بیم و 7 بیم مشاهده شد. مقادیر شاخص شیب دز تجمعی (Cumulative DOSE gradient index یا cDGI) میانگین اعدادکوچک تری در تکنیک IMRT 7 بیم نسبت به دو تکنیک دیگر نشان داد. نتیجه گیری: سه تکنیک IMRT 3، 5 و 7 فیلد اختلاف آماری چشم گیری از نظر میزان افت دز در بعد از مرزهای تومور نسبت به یکدیگر ندارند و انتخاب آن ها در درمان مننژیومای عصب بینایی به صلاح دید پزشک مربوط با توجه به شرایط هر بیمار بستگی دارد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 643

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 148 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2021
  • دوره: 

    11
  • شماره: 

    3
  • صفحات: 

    263-270
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    105
  • دانلود: 

    0
چکیده: 

Background: 90Y and 177Lu are two well-known radionuclides used in radionuclide therapy to treat neuroendocrine tumors. Objective: This current study aims to evaluate, compare and optimize tumor therapy with 90Y and 177Lu for different VOLUMEs of the tumor using the criterion of self-absorbed DOSE, cross-absorbed DOSE, absorbed DOSE profile, absorbed DOSE uniformity, and DOSE-VOLUME HISTOGRAM ((DVH)) curve using Gate Monte Carlo simulation code. Material and Methods: In our analytical study, Gate Monte Carlo simulation code has been used to model tumors and simulate particle transport. Spherical tumors were modeled from radius 0. 5 to 20 mm. Tumors were uniformly designed from water (soft tissue reagent). The full energy spectrum of each radionuclide of 177Lu and 90Y was used in the total VOLUME of tumors with isotropic radiation, homogeneously. Self-absorbed DOSE, cross-absorbed DOSE, absorbed DOSE profile, absorbed DOSE uniformity, and (DVH) curve parameters were evaluated. Results: The absorbed DOSE for 90Y is higher than 177Lu in all tumors (p-value <5%). The uniformity of the absorbed DOSE for 177Lu is much greater than 90Y. As the tumor size increases, the (DVH) graph improves for 90Y. Conclusion: Based on self-absorbed DOSE, cross-absorbed DOSE, absorbed DOSE uniformity, and (DVH) diagram, 177Lu and 90Y are appropriate for smaller and larger tumors, respectively. Next, we can evaluate the appropriate cocktail of these radionuclides, in terms of the type of composition, for the treatment of tumors with a specific size.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 105

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1401
  • دوره: 

    40
  • شماره: 

    682
  • صفحات: 

    587-592
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    87
  • دانلود: 

    44
چکیده: 

مقدمه: سرطان پستان، شایع ترین نوع سرطان بدخیم زنان در کل جهان و دومین سرطان کشنده در میان زنان پس از سرطان ریه است. این مطالعه، با هدف مقایسه ی تفاوت های دزیمتریک بر اساس دو طرح درمان پرتودرمانی برای سرطان پستان چپ بعد از عمل جراحی بود. روش ها: اطلاعات سی تی اسکن 20 بیمار کاندید پرتودرمانی مبتلا به سرطان پستان چپ که به طور تصادفی ساده انتخاب شدند به نرم افزار طراحی درمان ارسال گردید. اندام هدف (پستان چپ) و اعضای در معرض خطر شامل ریه ها، قلب، پستان راست توسط رادیوآنکولوژیست کانتور گردید. طراحی درمان پرتودرمانی تطبیقی سه بعدی (Three-dimensional conformal radiotherapy) 3D-CRT با استفاده از دو پرتو مماس مخالف هم، بستگی به آناتومی بیمار با و بدون وج و انرژی 6 مگاولت طراحی گردید. طراحی درمان توموتراپی با انرژی 6 مگاولت انجام شد. در آخر، با استفاده از منحنی توزیع دز-حجم (DOSE-VOLUME HISTOGRAM) (DVH) متغیرهای دزیمتری اندام هدف و اندام های در معرض خطر استخراج و با یکدیگر مقایسه گردید. یافته ها: روش پرتودرمانی تطبیقی سه بعدی نسبت به روش توموتراپی، میانگین دز اندام هدف و اندام های در معرض خطر را کاهش داد. شاخص انطباق و شاخص همگنی در روش توموتراپی بهبود یافت، اگرچه پوشش حجم اندام ریه ی چپ در دزهای پایین نسبت به روش پرتودرمانی تطبیقی سه بعدی افزایش پیدا کرد. نتیجه گیری: روش توموتراپی نسبت به روش پرتودرمانی تطبیقی سه بعدی، به دلیل بهبود پوشش حجم هدف و توزیع دز بهتر، روش مناسب تری برای درمان می باشد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 87

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 44 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1402
  • دوره: 

    41
  • شماره: 

    706
  • صفحات: 

    35-41
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    100
  • دانلود: 

    39
چکیده: 

مقدمه: سرطان نازوفارنکس، یکی از سرطان های رایج سر و گردن است که درمان اصلی برای این نوع سرطان، رادیوتراپی می باشد. هدف این مطالعه، بررسی و مقایسه ی دوز ارگان های در معرض خطر در دو روش سه بعدی تطبیقی و توموتراپی مارپیچی در بیماران مبتلا به سرطان سر و گردن می باشد. روش ها: مطالعه ی حاضر از نوع گذشته نگر و تجربی مقطعی می باشد. برای انجام این مطالعه، تصاویر سی تی اسکن 16 بیمار مبتلا به مراحل اولیه ی سرطان نازوفارنکس با میانگین سنی 81-16 سال (3/16 ±,7/42) که به صورت تصادفی انتخاب شدند، دریافت شد. ارگان های در معرض خطر و حجم هدف آن ها توسط پزشک کانتور شد و طرح درمان بیماران برای دو روش (Helical Tomotherapy) HT و 3D-CRT (Three-Dimensional Conformal Radiation Therapy) طراحی گردید. در پایان با استفاده از هیستوگرام حجم-دوز (VOLUME-DOSE HISTOGRAM) (DVH) متغیرهای دزیمتری ارگان های در معرض خطر و حجم هدف استخراخ و با یکدیگر مقایسه شد. یافته ها: روش HT نسبت به 3D-CRT شاخص همگنی و شاخص تطابق را بهبود بخشید. همچنین دوز OAR مورد مطالعه را نسبت به 3D-CRT به طور معنی داری کاهش داد، گرچه دوز برخی از این ارگان ها از محدودیت دوز تعیین شده خارج شدند. نتیجه گیری: روش HT به دلیل پوشش دهی بهتر حجم هدف و همچنین عملکرد بهتر در حفظ OARها نسبت به روش 3D-CRT برای درمان بیماران مبتلا به سرطان نازوفارنکس که کاندید دریافت رادیوتراپی هستند، ارجحیت دارد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 100

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 39 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 4
نویسندگان: 

Hanumantarao Sridhar Chintamani, Senthiappan Athiyamaan Mariappan

اطلاعات دوره: 
  • سال: 

    2022
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    135-142
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    60
  • دانلود: 

    0
چکیده: 

Background: The present study aimed to evaluate dosimetrically and correlate the lung and heart DOSE VOLUME HISTOGRAM ((DVH)) of the 4 field three-dimensional conformal radiotherapy (3DCRT) with 7 field intensity modulated radiotherapy (IMRT) in patients with oesophageal cancers. Method: This retrospective dosimetric study considered 20 oesophagus cancer patients treated with definitive chemoradiation with IMRT technique. In the 7 field IMRT technique, the first phase delivered a DOSE of 36Gy/18fr followed by 18Gy/9fr in two weeks in the second phase. In the 3DCRT technique, the first phase was planned with 4 field technique with two parallel opposed and two posterior oblique fields, followed by the 3 field technique in the second phase. The assessments of the techniques were performed using differential (DVH) analysis of the right and left lungs, heart, and the spinal cord. The values of the mean DOSE, V20 (VOLUME receiving 20 Gy), and V30 (VOLUME receiving 30 Gy) were assessed for any correlations. Results: The (DVH) of V20 in IMRT showed 5% less lung VOLUME irradiation compared with the 3DCRT plans and over 20% less V30 for irradiated heart VOLUME. The study demonstrated a statistical advantage of using 7 field IMRT over 4 field 3DCRT in reducing the mean percentage DOSE to both lungs, heart, and spinal cord. Conclusion: 7 field IMRT is superior to 4 field 3DCRT plans in significantly reducing the average percentage of irradiated VOLUME of both the lung and heart in esophageal cancer radiation therapy.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 60

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

SOLIMAN MAHER

اطلاعات دوره: 
  • سال: 

    2016
  • دوره: 

    7
  • شماره: 

    3
  • صفحات: 

    137-143
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    344
  • دانلود: 

    0
چکیده: 

Background: Radiation-induced lung toxicity is an important DOSE-limiting toxicity in lung cancer radiotherapy, for which there are no generally accepted predictive factors. This study seeks to identify risk factors associated with the development of severe radiation-induced lung toxicity using clinical and dosimetric parameters.Methods: We reviewed the medical records of 54 patients with histologically proven stage III non-small cell lung cancer treated with three dimensional-conformal radiotherapy at Alexandria Main University Hospital between January 2008 and December 2011. The original treatment plans for those patients were restored and imported to a treatment planning system. Lung DOSEVOLUME HISTOGRAMs and various dosimetric parameters were calculated. Univariate and multivariate logistic regression analyses were performed.Results: The following grades of radiation-induced lung toxicity were observed in patients - grade 0: 17 (31.5%), grade 1: 5 (9.3%), grade 2: 13 (24.1%), grade 3: 15 (27.8%), and grade 5: 4 (7.4%). A total of 19 (35.2%) patients developed grade ≥3 and were considered to have an event. Univariate analysis showed that age, presence of chronic obstructive pulmonary disease and location of the primary tumor had significant associations with severe radiation-induced lung toxicity. Other dosimetric variables such as tumor side, histology, forced expiratory VOLUME in 1 s, smoking, and gender showed no significant correlations with severe radiation-induced lung toxicity. Multivariate analysis showed that the presence of chronic obstructive pulmonary disease (P=0.001) and location of the primary tumor (P=0.010) were the only predictive factors for severe radiation-induced lung toxicity.Conclusion: This study demonstrates that patients with chronic obstructive pulmonary disease and lower lung lobe tumors have a high risk of severe radiationinduced lung toxicity when treated with combined chemoradiotherapy. These easily obtained clinical factors should be considered when calculating the risk for radiationinduced lung toxicity.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 344

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button