Search Results/Filters    

Filters

Year

Banks




Expert Group










Full-Text


Issue Info: 
  • Year: 

    1393
  • Volume: 

    21
Measures: 
  • Views: 

    261
  • Downloads: 

    0
Abstract: 

لطفا برای مشاهده چکیده به متن کامل (pdf) مراجعه فرمایید.

Yearly Impact:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 261

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0
Issue Info: 
  • Year: 

    2023
  • Volume: 

    13
  • Issue: 

    3
  • Pages: 

    105-121
Measures: 
  • Citations: 

    0
  • Views: 

    182
  • Downloads: 

    14
Abstract: 

A B S T R A C T Temperature is one of the climate elements that has fluctuated a lot over time. When these fluctuations increase and decrease more than normal and are placed in the upper and lower regions of the statistical distribution, if continued, it can lead to the creation of heating and cooling waves. The purpose of this study is to analyze the temporal and spatial changes in heating and cooling waves in Iran during a period of 50 years. For this purpose, the temperature of 663 synoptic stations from 1962 to 2004 was obtained from the Esfazari database. Then, in order to complete this database, the daily temperature from 2004 to 2011 was obtained from the Meteorological Organization of the country and added to the aforementioned database. In order to perform calculations and draw maps, Matlab, grads and Surfer software have been used. The results of this study showed that the index of cooling waves and heating waves, while having a direct effect on each other, had an increasing trend in most of the area of Iran. The statistical distribution of the index of cooling waves is more heterogeneous than that of the index of heating waves. So that the spatial variation coefficient for cold waves is 84.22%. Also, the index of cooling waves has more spatial variability. The highest common diffraction of the index of heating and cooling waves has been seen in the northwest, east and along the Zagros mountains. Analysis of the indexes trends show that heat waves have intensified in 65.8% of Iran and the intensity of cold waves has decreased in 48.5% of Iran Extended Abstract Introduction Temperature is one of the major climatic variables, which it has a direct impact on different aspects of human life. It plays an essential role in the growth of crops and is considered a key driver of the biological system(Reicosky et al, 1988). It is associated with several types of extremes, for example, heat and cold waves which caused human societies maximum damage. Past occurrences of heat waves hitherto had significant impacts on several aspects of society. Have increased Mortality and morbidity. Ecosystems can be affected, as well as increased pressure on infrastructures that support society, such as water, transportation, and energy(Dewce, 2016). The long-term change of extreme temperatures has a key role in climatic change. The form of statistical distribution and the variability of mean values and also extreme event indicate a change in the region. It can be a small relative change in the mean as a result of a large change in the probability of extreme occurrence. Also, the variation in temperature data variance is significantly more important than the mean, for assessing the extreme occurrence of climate(Toreti and Desiato, 2008). The average surface temperature has increased the world between 0.56 and 0.92 ° C over the past 100 years(IPCC, 2007). Meanwhile, it was in the Middle East, the average daily temperature increased by 0.4-0.5 ° C in decades(Kostopoulou et al, 2014; Tanarhte et al, 2012). Considering that not many studies have been done in the field of spatio-temporal Variations of the heating and cooling waves thresholds in Iran, in this study, the spatio-temporal Variations of the heating and cooling waves thresholds in Iran during 50 years were examined and analyzed.   Methodology The daily temperature from the beginning of the year 21/03/1967 to 19/05/2005 was obtained from the Esfazari database prepared by Dr. Masoudian at the University of Isfahan. In order to increase the time resolution of the mentioned database, the daily temperature of observations from 05/21/2005 to 05/12/2012 has been added to the mentioned database using the same method, and the exact spatial resolution (15 x 15 km) is used as a database. Threshold indices of heating waves are the average numbers between the 95th and 99th percentiles, that is, the extreme hot threshold to the limit of excessively extreme hot. For extreme cool, from the 5th percentile down to zero is used. Of course, a condition was added to these thresholds, which is that these thresholds must be repeated two days in a row. These thresholds were extracted for each day in the 50 years of the study period and used as the original database. In order to analyze the relationship between cooling and heating waves, Pearson's correlation coefficient was used and regression was used to analyze the trend.   Results and discussion The average of cold waves was 5.26 ° C and for the heat waves is 30.20° C. Generally, if the temperature is upper or lower than this threshold, it is considered as hot or cold temperatures. A comparison of the median, mode, and average of cold waves with heat waves shows that the distribution is more heterogeneous for cold waves and its CV is 84.22%. In southern Iran, the average threshold heat waves are higher. This situation can be caused by the effects of subtropical high-pressure radiation, low latitude, and proximity to the sea. Though the threshold is higher in these areas, fewer fluctuations and changes are seen in the area. Heights moderate the temperature so they pose a minimum threshold for heat waves i.e. an iso-threshold of 25 ° C is consistent along the Zagros mountain chains, but in the west and east of Zagros Mountains, the threshold of heat waves is increased. Heat waves have increased in most areas of the country. So nearly 85 percent of the Iran has been an increasing trend, of which 65.8 percent is statistically significant at the 95% confidence level. Still, more areas of the country (60 percent) have a trend between 0.00828 and 0.00161. As can be seen, only 15% of the land area (including the southwest and northwest of the Country) had decreased heat waves. Cold waves, in most parts of the country, have a Positive Trend. However, about 25 percent of the study area's cold waves have a negative trend. they are located in areas higher than Latitude 30°. The largest decline of the wave's trend along the country is highlands. Nowadays, most of the country, has a trend between 0.01494 and 0.00828 ° C, respectively. Conclusion Common changes and effects of heat and cold waves had a direct relationship in many parts of the country. It is remarkable common variance in the East reached 55 percent, according to statistical significance. In some areas of the northwest and southwest, which have been impressive heights, the common variance is 40 percent. This common variance in mountains area has been high values. Investigation of heat waves trend shows that 65.8% of Iran significant positive trend and 7.1% significant negative trend. Also, the cold waves trend has indicated a 48.5% significant positive trend and a 10.8% significant negative trend. Climate change and global warming have changed the frequency and severity of temperature extremes. The present study, by examining the number of warm waves, concluded that the warm waves have increased in magnitude in 65.8% of the Iran zone. Also, the study of the cold waves trend showed that 48.5 percent of Iran had a positive trend, which means that the amount of temperature in the cold waves increased In other words, the severity of the cold has been reduced And only 10.8 percent of Iran had a negative cold wave trend And it shows the intensity of these waves is reduced.   Funding There is no funding support.   Authors’ Contribution The authors contributed equally to the conceptualization and writing of the article. All of the authors approthe contenttent of the manuscript and agreed on all aspects of the work declaration of competing interest none.   Conflict of Interest The authors declared no conflict of interest.   Acknowledgments  We are grateful to all the scientific consultants of this paper.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 182

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 14 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    1394
  • Volume: 

    30
Measures: 
  • Views: 

    350
  • Downloads: 

    0
Abstract: 

لطفا برای مشاهده چکیده به متن کامل (PDF) مراجعه فرمایید.

Yearly Impact:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 350

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0
Author(s): 

GHIABAKLOU Z.

Journal: 

HONAR-HA-YE-ZIBA

Issue Info: 
  • Year: 

    2001
  • Volume: 

    -
  • Issue: 

    8
  • Pages: 

    93-99
Measures: 
  • Citations: 

    0
  • Views: 

    952
  • Downloads: 

    0
Abstract: 

In many countries, there is a growing interest in utilizing passive and low energy systems tor heating and cooling of buildings. Electricity consumption associated with air conditioning systems in buildings, makes serious problems Such as nonrenewable resource dimination and environmental pollution.Based on the geographical location at Iran which is mostly located in a semi-arid climate, applying an evaporative cooling system could be a useful idea.This paper is concentrated on the performance at some passive evaporative cooling systems.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 952

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2021
  • Volume: 

    21
  • Issue: 

    7
  • Pages: 

    441-452
Measures: 
  • Citations: 

    0
  • Views: 

    910
  • Downloads: 

    0
Abstract: 

The Heller towers are the most common types of power plants cooling towers، where their efficiency is very sensitive to wind. According to the general approach of cooling systems designer، Direct dry cooling (ACC) systems are more popular today in power plants located in arid areas. In Heller towers due to the empty space inside them, in this study, instead of proposing the replacement of ACC towers, the hybrid model is proposed, where steam is Directly passed into the ACC radiators without fan installed inside the Heller Tower, and condenses with a natural suction mechanism. The flow around the proposed model is investigated in three dimensions in two cases of no wind and at 8 different wind speeds with the assumption of incompressibility flow by the continuity, momentum, energy, and turbulence equations. The hybrid tower performance has been compared with the Fars power plant cooling system and it has been shown that the proposed cooling tower has performed 25% better than the Fars cooling system in no wind condition. It has also performed better in wind conditions at different speeds except for speeds above 12. 5 m/s at a parallel and vertical array with the wind of ACCs. A vertical array of ACCs performance has been better than the parallel array. Therefore, the hybrid model with a vertical array of ACCs can be efficient to replace the cooling system of the Fars power plant.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 910

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2023
  • Volume: 

    16
  • Issue: 

    7
  • Pages: 

    1386-1401
Measures: 
  • Citations: 

    0
  • Views: 

    39
  • Downloads: 

    11
Abstract: 

In order to cool the gas turbine vane or blade and raise the operating temperature, two standard convective cooling methods are used: jet impingement cooling and film cooling. The current study uses computational analysis to analyze and compare film cooling effectiveness with and without multi-jet impingement cooling on a flat plate. Ansys Fluent software is used to perform computational analysis on a flat plate. The computational results were compared with the experimental result using K-ω SST turbulence model and validated with literature data. The flat plate is used for the conjugate heat transfer study on the hot surface (named interaction surface), cold surface (called target surface), and inside the film hole. Different heat transfer parameters such as heat flux, Nusselt's number, and effectiveness are compared for the two cases, i. e., film cooling with impinging jets (IFC) and film cooling without impingement cooling (FC). It is observed that the FC case shows lower effectiveness as compared to the IFC case. The average Nusselt number for the IFC cases is almost three times larger than FC. The film exit temperature values are higher FC case, but it is more uniform in the IFC case. Interaction surface heat flux and Nusselt number values show higher values on the upstream wall of the film hole for IFC than in the FC case.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 39

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 11 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2011
  • Volume: 

    -
  • Issue: 

    1 (55)
  • Pages: 

    1-7
Measures: 
  • Citations: 

    0
  • Views: 

    975
  • Downloads: 

    0
Abstract: 

In this paper, the effect of cooling rate of a cooling system on performance of a centrifuge machine has been studied experimentally. The cooling rate is increased by temperature variation and volumetric flow rate of the inlet water to the cooling system. The results showed that the effect of cooling rate on separative work unit (SWU), heads and tails separation factors i.e. a and β are negligible. Also, if the cooling rate is less than a minimum value, the heat produced by moving machine elements cannot be dissipated and some elements of machine may be destroyed.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 975

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

DENG J. | WANG R. | HAN G.

Issue Info: 
  • Year: 

    2011
  • Volume: 

    37
  • Issue: 

    2
  • Pages: 

    172-203
Measures: 
  • Citations: 

    1
  • Views: 

    244
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 244

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2013
  • Volume: 

    13
  • Issue: 

    8
  • Pages: 

    57-67
Measures: 
  • Citations: 

    0
  • Views: 

    960
  • Downloads: 

    0
Abstract: 

The transformation behavior and microstructural characteristics of API X65 pipeline steel were investigated by dilatometry and microstructural observation. Microhardness measurements were used to verify the observed microstructures. The test steel is imported from abroad and is used extensively in Iran natural gas transmission projects. The continuous cooling transformation curves of the test steel were constructed. The results showed that with increasing the cooling rate from 0.5 to 40oC/s, the microstructure changed from polygonal ferrite, quasi-polygonal ferrite-pearlite to acicular ferrite. The microstructure was dominated by acicular ferrite in cooling rates higher than 5oC/s. The results can be used to design the optimum thermo-mechanical control process (through the selection of proper cooling rate) in domestic manufacturing of the test steel.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 960

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 2
Journal: 

BINA

Issue Info: 
  • Year: 

    2010
  • Volume: 

    15
  • Issue: 

    4 (61)
  • Pages: 

    284-288
Measures: 
  • Citations: 

    0
  • Views: 

    659
  • Downloads: 

    0
Abstract: 

Purpose: To compare post-operative pain with cooling photorefractive keratectomy (PRK) versus conventional PRK.Methods: A prospective clinical trial was performed on 94 eyes from 47 patients scheduled for PRK. Patients were randomly assigned to either cooling or conventional PRK. Pain was evaluated 6, 12, 24 and 48 hours post-operation using a visual analogue scale (VAS). Corneal haze, conjunctival and palpebral edema, and complications were also assessed.Results: Mean age of the patients was 24.8±4.5 (range: 18-36 years) and mean refractive error was 3.6±1.6 diopters. Median pain score in the cooling group at 6 and 12 hours was 15 and 10, respectively and zero at 24 and 48 hours. Median pain score in the conventional group at 6 and 12 hours was 30 and 15 and was zero at 24 and 48 hours. There was no adverse effect in either of the groups.Conclusion: Cooling PRK effectively reduces post-operative pain after PRK without any additional adverse effect.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 659

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button