Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

مشخصات نشــریه/اطلاعات دوره

نتایج جستجو

2558

نتیجه یافت شد

مرتبط ترین ها

اعمال فیلتر

به روزترین ها

اعمال فیلتر

پربازدید ترین ها

اعمال فیلتر

پر دانلودترین‌ها

اعمال فیلتر

پر استنادترین‌ها

اعمال فیلتر

تعداد صفحات

27

انتقال به صفحه

آرشیو

سال

دوره(شماره)

مشاهده شمارگان

مرکز اطلاعات علمی SID1
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1395
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    15-22
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1935
  • دانلود: 

    627
چکیده: 

امروزه بتن به عنوان یکی از پرمصرفترین مصالح ساختمانی در جهان شناخته شده است. میکروسیلیس و فرآورده های آن در حال حاضربه عنوان یکی از بهترین مواد افزودنی معدنی بتن شناخته می شود. میکرو سیلیس عمدتا برای بهبود خواص بتن سخت شده به کار می رود. اگرچه تاکنون آزمایش های گوناگونی در مورد این موضوع انجام گرفته است ولی این مقاله در نظر دارد تاثیر دیگر فراورده های سیلیس را بر روی خواص بتن سخت شده بررسی کند که شامل مقاومت فشاری، نفوذپذیری و ذوب-یخبندان بتن سخت شده می باشد. در این راستا سه نسبت اختلاطی در آزمایشگاه مورد آزمایش قرار گرفته است: نسبت اول بدون مواد افزودنی و با عیار 350 کیلوگرم بر مترمکعب سیمان، نسبت اختلاط دوم با وجود 10 درصد پودر میکروسیلیس و یک درصد فوق روان کننده و نسبت اختلاط سوم با 10 درصد میکروژل. براساس کار آزمایشگاهی انجام یافته در این پژوهش و باجمعبندینتایجخواصبتنسخت شده می توان بیان کرد، استفاده از پودر و ژل میکروسیلیس مقدار مقاومت فشاری را به ترتیب 37.5 و 56 درصد افزایش داد. میزان نفوذ آب در مقایسه با نسبت اول، در نسبت دوم 50 درصد افزایش یافته و در نسبت سوم 25 درصد کاهش یافته است. نتایج نشان دهنده ی مطلوب بودن تاثیرات دراز مدت ژل میکروسیلیس بر کیفیت بتن سخت شده از جمله دوام آن است. در حالیکه پودر میکروسیلیس، تاثیر نامطلوبی بر میزان نفوذپذیری و ذوب-یخبندان بتن داشت.

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1935

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 627 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1395
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    1-13
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1522
  • دانلود: 

    551
چکیده: 

سیستمهای اتلاف انرژی در سازه ها در چند دهه اخیر به طور گسترده برای کاهش نیروهای ناشی از زلزله و باد و همچنین کاهش جابجایی های ساختمانها در حد مجاز آیین نامه ای مورد استفاده قرار گرفته اند. یک نوع از این مستهلک کننده ها به عنوان سیستم های کنترل غیرفعال، میراگرهای ویسکوز می باشند که مورد توجه پژوهشگران زیادی قرار گرفته اند. میراگرهای ویسکوز از یک پیستون روزنه دار درون سیلندری که حاوی سیالی با غلظت زیاد می باشد تشکیل شده اند. استهلاک این میراگر از طریق هل دادن و عبور سیال چسبنده از سوراخهای پیستون انجام می شود. این میراگرها بر دو نوع خطی و غیرخطی می باشند که نوع کاربردی و معمول آن میراگرهای خطی با ضریب توانی سرعت یک می باشد. درعمل مقادیر مناسب نیروی میرایی این سازه ها با توجه به روش شرح داده شده در FEMA273 تعیین شده و در سه حالت کنترل شده توسط تغییرمکان، سرعت و شتاب، بدست می آیند.در این تحقیق، به بررسی تاثیر افزودن میراگرهای ویسکوز برپاسخ لرزه ای قابهای خمشی پرداخته شده است.برای این منظور سه قاب خمشی فولادی با 3 دهانه، و تعداد طبقات 1، 3 و6 و میراگرهایی ویسکوز با ضریب توانی 1، 0.8 و 0.6 انتخاب شده اند. این سازه ها تحت تحلیل های تاریخچه زمانی غیرخطی با نرم افزار Opensees ناشی از سه شتاب نگاشت ال سنترو، کوبه و نرتریج قرار گرفته و پاسخ آنها شامل تغییرمکان، شتاب و برش پایه در حالت با و بدون میراگرهای ویسکوز با یکدیگر مقایسه شده است. در پایان با توجه به پاسخ آنها در سه حالت کنترل شده توسط تغییرمکان، سرعت وشتاب، نیروی میرایی مناسب آنها بر مبنای شتاب و برش پایه حداکثر بدست آمده از FEMA273 برای سازه 1 طبقه 94.7، 3 طبقه 240.1 و سازه 6 طبقه 557.1 کیلونیوتن تعیین شده است.

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1522

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 551 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1395
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    57-66
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1102
  • دانلود: 

    489
چکیده: 

امروزه در اکثر نقاط دنیا تحول عظیمی در تکنولوژی بتن برای دستیابی به بتن های با مقاومت بالا پدید آمده است. کاربرد متاکائولین در بتن برای دستیابی به بتن های با مقاومت بالا و با دوام، چند سال است که در صنعت بتن جا باز نموده است. ریزی نسبی بسیار زیاد و فعالیت پوزولانی قابل ملاحظه و ایجاد واکنش با هیدروکسید کلسیم موجود در سیمان، این ماده سبب کاهش تخلخل و نفوذپذیری و افزایش دوام و مقاومت در بتن ها شده است. در این تحقیق نقش متاکائولین و تاثیر آن بر خواص مکانیکی و پایایی بتن و رسیدن به درصد بهینه استفاده از متاکائولین جهت کسب مقاومت بالا و دوام مناسب مورد بررسی قرار گرفته است. در این تحقیق تست های آزمایشگاهی که شامل بررسی روانی، درصد جذب آب، وزن مخصوص بتن، تست مقاومت الکتریکی (که نشان دهنده ی میزان خوردگی و نفوذپذیریست) و تست مقاومت فشاری بر روی نمونه هایی با 0، 10، 15و 20 درصد متاکائولین جایگزین سیمان در شرایط سنی 7 و 28 روزه بر روی نمونه 15x15 سانتیمتری ساخته شده صورت پذیرفته است. نتایج بدست آمده نشانگر آن بوده که افزودن 10 درصد متاکائولین جایگزین سیمان در آزمایش اسلامپ، 15 درصد متاکائولین جایگزین سیمان در آزمایش مقاومت فشاری و20 درصد متاکائولین جایگزین سیمان در آزمایش مقاومت الکتریکی بیشترین مقادیر و افزودن 15 درصد متاکائولین جایگزین سیمان در آزمایش وزن مخصوص بتن و 20 درصد متاکائولین جایگزین سیمان در آزمایش درصد جذب آب کمترین میزان را نسبت به دیگر طرح های ساخته شده از خود نشان داده اند.

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1102

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 489 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

ZAHRAI SEYED MEHDI | MOHAMADI OMID

اطلاعات دوره: 
  • سال: 

    2016
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    1-14
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    207
  • دانلود: 

    0
چکیده: 

Energy dissipation systems have been broadly used in structures during the recent decades in order to reduce earthquake and wind forces as well as reduction of structural lateral drifts within the code limits. Viscous damper is considered as one of the energy dissipation systems which are classified as velocity-dependent dampers among passive control systems and have been paid attention and their further detailed properties taken into account by many researchers. Viscous damper consists of a piston with some orifices inside the cylinder which contains highly viscous fluid. Energy dissipation of this damper is through pushing viscous fluid out of the orifices.These are two types of these dampers: linear and nonlinear from which linear type with velocity power of one is more practical. The structural damping force is usually set according to the procedure described in FEMA273 and are optimized by three controlled modes of displacement, velocity and acceleration.This study examines the effect of adding viscous dampers on seismic behavior of steel moment frames. For this purpose, three steel moment frames of 1, 3 and 6-story all in 3 bays, with viscous dampers having power factor of 1, 0.8 and 0.6 are selected. These sample structures are subjected to the nonlinear time history analysis under the El Centro, Kobe and Northridge earthquakes, and their response including displacement, acceleration and base shear is compared in two cases of with and without viscous dampers.Finally, regarding nonlinear time history analysis results based on the structural behavior in three modes controlled by displacement, velocity and acceleration, proper damping forces are specified as 94.7, 240.1 and 557.1 kN respectively for one, three and six story structures based on maximum acceleration and base share obtained from FEMA273.

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 207

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

MALEKI AHMAD | ESMAEILI FARDIN

اطلاعات دوره: 
  • سال: 

    2016
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    15-23
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    212
  • دانلود: 

    0
چکیده: 

Today, concrete is known as one of the most used building materials in the world. Silica fume and its products are now known as one of the best mineral additives in concrete. Silica fume is mainly used to improve the properties of hardened concrete so when using Silica fume concrete properties after hardening usually more significant. But although various experiments have been conducted on the subject. But this thesis is considering other products of silica impact on the hardened concrete properties have been investigated, including compressive strength, permeability and Thawing -freezing of hardened concrete. Three mixing ratio is tested in the laboratory: 1- without additives and 350 kg per cubic meter of cement, 2- with 10% Silica fume powder and one percentage lubricant, 3- with 10% of the micro gel. Based on lab work conducted in the research and the gathering of results can be explained by the properties of hardened concrete, the use of powder and gel of Silica fume increased compressive strength of 37.5 and 56 percent respectively. Water penetration rate, in the second ratio increase 50 percent and in the third ratio decreased 25 percent, compared to the first ratio. The results indicate the desirability of Silica fume gel long-term impact on the quality of hardened concrete including its durability. While the silica fume powder, could adversely affect the permeability and Freezing-Thawing of concrete.

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 212

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1395
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    23-32
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    849
  • دانلود: 

    865
چکیده: 

بسیاری از ساختمان ها در زلزله های گذشته در اثر وقوع طبقه نرم دچار خسارت و ویرانی گردیده اند. عوامل متعددی همچون ارتفاع بلندتر یا حذف تعدادی از ستون ها، حذف مهاربندی های جانبی، دیوارهای برشی و یا میانقاب ها به دلایل معماری در یکی ازطبقات به ویژه در طبقه همکف علت اصلی وقوع این پدیده به شمار می رود. بر این اساس اکثر آیین نامه های لرزه ای، ضوابطی را جهت جلوگیری از ایجاد طبقه نرم ارائه نموده اند، اکثر این ضوابط نسبت هایی را بین سختی طبقات مجاور درنظر گرفته اند لیکن روش همسانی جهت محاسبه سختی طبقات ارائه نکرده اند، اکثر پژوهش-های انجام شده در خصوص سختی نیز، بر روی روش های تقریبی متمرکز بوده و کمتر به روش های دقیق و نرم افزاری پرداخته شده است. در این پژوهش نخست پدیده طبقه نرم و روش های محاسبه سختی در ادبیات بررسی و سپس شش روش دقیق (نرم افزاری) جهت محاسبه سختی طبقات از طریق تحلیل قاب های بتنی دو بعدی مطالعه گردیده است. بر اساس نتیجه تحلیل ها، روش سوم که در آن بدون هیچ گونه تغییر در مدل اصلی، نیروهایی با توزیع مثلثی مشابه نیروی زلزله بر مرکز جرم کلیه طبقات اعمال شده و از طریق محاسبه تغییرمکان نسبی هر طبقه، سختی آن طبقه محاسبه می شود، از دقت قابل قبول و کارایی مطلوبی برای طراحی سازه برخوردار می باشد.

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 849

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 865 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1395
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    33-43
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1365
  • دانلود: 

    1047
چکیده: 

از جمله موارد دخالت بشر در محیط زیست، تغییرات قابل توجه در نفوذ ناپذیر نمودن بخش هایی از سطح زمین و به تبع آن تغییر در چرخه آب می-باشد. بتن متخلخل نوع خاصی از بتن با تخلخل بالاست که با محیط زیست سازگار بوده و می توان از آن به عنوان یکی از روش های نفوذپذیر نمودن سطح زمین و کاهش حجم رواناب شهری استفاده نمود. در پژوهش آزمایشگاهی حاضر، به منظور بهبود عملکرد این نوع بتن، اثر اضافه کردن سبک‏دانه های پوکه معدنی و پرلیت (با اندازه 0.6 تا 1.2 میلی متر) و همچنین افزودن 10 % وزنی ریزدانه به نمونه ها مورد بررسی قرار گرفت. در این راستا، پارامترهای تاثیرگذار برای استفاده از بتن متخلخل در سیستم رواناب شهری نظیر مقاومت فشاری، ضریب نفوذپذیری و درصد تخلخل برای نمونه ها اندازه گیری شد. تحلیل نتایج آزمایشگاهی با استفاده از نرم افزار SAS 9.4 در سطح اطمینان 95 % برای تمامی نمونه ها انجام گردید. نتایج نشان داد که با افزودن ریزدانه به بتن متخلخل، مقاومت فشاری افزایش و ضریب نفوذپذیری و درصد تخلخل کاهش می یابد. افزودن سبک‏دانه پوکه معدنی نیز باعث افزایش مقاومت بتن متخلخل و کاهش ضریب نفوذپذیری و درصد تخلخل گردید. اما سبک‏دانه پرلیت، به دلیل وزن مخصوص کم، علاوه بر کاهش ضریب نفوذپذیری و در صد تخلخل، منجر به کاهش مقاومت فشاری در نمونه های بتن متخلخل نیز شد. به طور کلی، سبک‏دانه پوکه معدنی به دلیل داشتن وزن مخصوص بیشتر نسبت به پرلیت و همچنین داشتن فضای خالی بیشتر در ساختمان داخلی خود دارای عملکرد بهتری بود.

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1365

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 1047 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1395
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    45-55
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    548
  • دانلود: 

    516
چکیده: 

به منظور کاهش یا حذف تغییرشکل های باقی مانده ایجاد شده در اعضای اصلی سازه پس از باربرداری زلزله، می توان از سیستم های خودمرکز استفاده نمود. یکی از روش های ایجاد خاصیت خودمرکزی در سازه ها، استفاده از اتصالات پس کشیده فولادی می باشد.در این تحقیق با استفاده از تحلیل عددی به روش اجزا محدود، به مطالعه رفتار اتصال پس کشیده فولادی همراه با نبشی های فوقانی و تحتانی پیچ شده به بال تیر و بال ستون، تحت بارگذاری چرخه ای پرداخته و با استفاده از مقایسه مقادیر شاخص های خسارت گوناگون، نقش عوامل مختلف در عملکرد این اتصال بررسی شده است. نتایج حاصل از این تحقیق نشان می دهد، با استفاده از روش پس کشیدگی، توان باربری اتصال افزایش قابل توجهی یافته درحالیکه تغییر شکل های باقی مانده در اعضای اصلی اتصال ناچیز می باشد. در یک اتصال پس کشیده ناحیه ماکزیمم تنش ایجاد شده در تیر بر روی بال تیر بوده و استفاده از ورق تقویت با طول بزرگتر سبب کاهش مقادیر تنش های ایجاد شده در تیر و کاهش شاخص های خسارت و درنتیجه کاهش احتمال وقوع گسیختگی ترد در نبشی های کششی اتصال می شود.

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 548

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 516 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2016
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    57-76
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    260
  • دانلود: 

    0
چکیده: 

Development of concrete technology is undergoing for achieving high strength concrete. Metakaolin (MK) for obtaining high strength and durable concrete recently is used in industry. The relatively high micro particles and pozolan activity and reaction with calcium hydroxide of cement, causes lower voids, permeability and increasing durability. In the present research the history of pozolans and their materials specially MK and their effects on mechanical properties to achieve an optimize percentage of MK instead of cement were investigated. The tests are included as workability, absorbing water, relative density, electric resistance (that shows permeability and corrosion resistance) and compressive strength. The tests were carried out on0%, 10%, 15% and 20% of MK in replacement of cement on 150x150mm samples on 7 and 28 days after casting. The results show that 10% of MK has better workability.15% of MK higher compressive strength and 20% higher electric resistance and lower absorbing water and15% have a reduced relative density

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 260

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1395
  • دوره: 

    13
  • شماره: 

    1
  • صفحات: 

    67-73
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    991
  • دانلود: 

    705
چکیده: 

با توجه به تصویب ویرایش چهارم استاندارد 2800 و لحاظ شدن تغییرات عمده نسبت به ویرایش سوم و همچنین تغییر مبحث ششم مقررات ملی، بررسی و ارزیابی آسیب پذیری ساختمان های طراحی و ساخته شده طبق ویرایش سوم استاندارد 2800 و مقایسه آن با خواسته های ویرایش جدید حائز اهمیت می باشد. در این تحقیق عملکرد لرزه ای چهار سازه بتن آرمه که بر مبنای ویرایش های سوم و چهارم آیین نامه 2800 و مبحث ششم مقررات ملی ویرایش سال 85 و 92 بارگذاری شده اند مورد ارزیابی قرار گرفته است. بطوریکه سازه ها بر اساس ویرایش سوم تحلیل و طراحی شده اند و به منظور مقایسه، ضوابط ویرایش چهارم استاندارد 2800 و مبحث ششم سال 1392 در همان سازه ها اعمال شده است. در نهایت پارامترهایی از قبیل مقدار آرماتور مورد نیاز المان های سازه ای، جابجایی نسبی واقعی طبقات و مقدار ضریب زلزله مقایسه شده اند. نتایج بدست آمده نشانگر تاثیر فراوان تحولات آیین نامه ای بر مقدار آرماتور مورد نیاز تیرها می باشد، درحالیکه تاثیر آن بر ستون ها بسیار ناچیز است.

آمار یکساله:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 991

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 705 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button