چکیده: 

Introduction: Assessment of radiation dose is an important task in radiation protection dosimetry whereas absorbed and effective dose measurements directly in body organs are impossible. So Monte Carlo simulations is necessary to estimate radiation dose. The method of dose calculation, the body model and the computational code can be mentioned as three main factors that have an affect on dosimetric quantities. The aim of this study is the determination of the above factors influence on the absorbed dose and effective dose evaluation. For this purpose different comparisons between the mathematical and the voxel phantoms were done.Methods: ORNL modified adult phantom is the mathematical phantom which is described by Cristy and Eckerman in 1987. This phantom is utilized for calculation of the absorbed dose. The effective dose is calculated according to the manner which is introduced in the ICRP reported 60 and 103.Results: All of the doses Evaluation have an uncertainty less than 0.5%. MCNPX code and ORNL modified adult phantom are applied for the dose assessment in the energy range 10-9 – 20 MeV, under AP, PA, RLAT, LLAT, ROT and ISo irradiation conditions. The results are then normalized to the unit of neutron fluence. The calculated absorbed dose was compared with ICRP74 data in 9 organs and with Bozkurt et al data in 18 organs. The effective dose was calculated for whole body. Then these data were compared with results of a mathematical phantom and some voxel models in different irradiation geometries.Conclusion: Although the absorbed dose results of ORNL show fewer differences with ICRP data than Bozkurt et al data, one can deduce neither complete agreement nor disparity between the ORNL data and the other two data sets. Totally 73% of the ORNL data in comparison with MIRD data and 48% of data in comparison with VIP_MAN results have difference less than 15%. Comparison of the ORNL effective dose with some male and female voxel phantoms (TARA, HANAKO, GSF, VIP_MAN) and an analytical model (MIRD) show that the changing of body model and computational code have few influence (less than 15%) on the effective dose results. But changing of wR and wT parameters have a significant effect on the results so that the largest discrepancies are about 100% on some data.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 234

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1399
  • دوره: 

    8
  • شماره: 

    2 (ویژه نامه پرتوهای غیریون ساز)
  • صفحات: 

    13-16
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    552
  • دانلود: 

    111
چکیده: 

آسیب حاصل از تابش به میران جذب انرژی بستگی دارد، و تقریباً با تراکم انرژی جذب شده در بافت متناسب است. در بررسی تابش خارجی با شار انرژی معین، مقدار دز جذب شده در هر نقطه از بافت به نوع تابش، انرژی تابش، فاصله عمق محل دریافت دز و اجزای اصلی سازنده محیط جاذب در آن نقطه بستگی دارد. در پرتو درمانی، میزان دز جذبی یا انرژی جذب شده در بافت حائز اهمیت است. این مسئله در خصوص پرتوهای یونساز همانند ایکس و گاما تقریباً شناخته شده است و در پروتکل های درمانی اجرا می گردد. لیکن در لیزر درمانی کمتر به آن توجه شده است. به علت وجود خطرات بالفعل در کار با لیزر، دزیمتری در لیزر درمانی بسیار حائز اهمیت است و علاوه بر رعایت حدود مجاز تابشی به لحاظ حفاظت پرتویی لزوماً میزان دز تابش جهت دستیابی به اثر مطلوب از الزامات این کاربرد لیزر در پزشکی است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 552

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 111 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1385
  • دوره: 

    9
  • شماره: 

    3 (پیاپی 31)
  • صفحات: 

    210-215
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1652
  • دانلود: 

    0
چکیده: 

هدف: تشعشعات کیهانی از فضای خارج به طور مستمر به سطح زمین می تابد. میزان پرتوگیری محیطی در آتمسفر زمین، به جز از فعالیتهای غیر معمول و گذرای خورشیدی، اغلب تابعی از عرض جغرافیایی و ارتفاع از سطح زمین است. این پرتوگیری در عرض جغرافیایی معتدل شمالی و در ارتفاع هواپیماها به میزان 20-25 برابر افزایش می یابد. بنابراین کادر پروازی و مسافرانی که به طور مکرر در پروازند به میزان زیادی در معرض این تابشهای کیهانی قراردارند. در این مقاله به جنبه های عمومی حفاظت پرتوی برای کادر پروازی که در پروازهای داخل کشور در معرض اشعه کیهانی قراردارند، توجه شده است.مواد و روش کار: میزان دوز محیطی در چندین پرواز داخلی با استفاده از سرویمتر مدل RDS-110 اندازه گیری شده است. بر مبنای اطلاعات اندازه گیری شده و مدت پرواز، دوز موثر کادر پروازی ابتدا محاسبه و سپس با نتایج  به دست آمده از نرم افزار CARI-6 که توسط انستیتو هوا - فضای شهری در شهر اکلاهمای امریکا معرفی شده، مقایسه گردیده است. به علت تطابق بسیار خوب مقادیر اندازه گیری با نتایج محاسبات، از برنامه مذکور برای تعیین میزان دوز در سایر ارتفاعات و در سراسر کشور استفاده شده و الگوریتم ساده ای برای محاسبه دوز مسیرهای مختلف در پروازهای داخلی ارایه گردیده است.نتایج: نتایج اندازه گیری ها نشان می دهد که میزان معادل دوز در ارتفاعات مربوط به پروازهای داخلی می تواند از رابطه a(h)b  محاسبه شود. در این رابطه h ارتفاع پرواز برحسب هزار پا، a و b ثابتهایی هستند که به محل جغرافیایی بستگی دارند. با استفاده از میزان معادل دوز و پرفایل پرواز، الگوریتم ساده ای برای برآورد دوز مسیر در پروازهای داخلی ارایه شده است.نتیجه گیری: حدود دوز سالانه عموم افراد جامعه به کادر پروازی این اجازه را می دهد که سالانه 290 ساعت پرواز در ارتفاعات 27-33 هزارپا را در پروازهای داخلی داشته باشند، و کارکنان زن در کادر پروازی در زمان حاملگی تنها می بایستی از پرتوگیری خود مطلع باشند.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1652

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1387
  • دوره: 

    7
  • شماره: 

    2 (مسلسل 57)
  • صفحات: 

    254-262
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1363
  • دانلود: 

    354
چکیده: 

هدف: پرتودرمانی یکی از راههای درمان سرطان است که در آن با تابش پرتوهای یونیزان به سلولهای تومورال، از تکثیر و رشد سلولها جلوگیری کرده و آنها را از بین می برند. هر چه میزان انرژی واگذار شده توسط پرتو یونیزان به ناحیه تحت درمان (دوز جذبی) بیشتر باشد، سلولهای تومورال بیشتری کشته می شوند. در این تحقیق به بررسی تاثیر دما بر دوز جذبی ناشی از پرتوتابی پرداخته ایم. هدف اصلی در پرتودرمانی، رسیدن دوز مناسب به صورت همگن به بافت تومورال و حفاظت بافتهای سالم اطراف تومور است.روش بررسی: دوز جذبی را در فانتوم آب با ابعاد 30´30´30 cm برای میدانهای با ابعاد (از 5´5 cm تا 20´20) تحت تابش گامای حاصل از چشمه کبالت 60 و در عمقهای 5 تا 9 سانتیمتر برای دماهای 30oC تا 50oC بوسیله اتاقک یونیزاسیون فارمر و الکترومتر همراهش اندازه گیری کردیم. سپس منحنی تغییرات دوز جذبی بر حسب دما را برای هر آزمایش رسم نمودیم و در ادامه با معرفی کمیت TER، درصد افزایش دوز در اثر تغییر دما را محاسبه و نمودار تغییرات آن را نیز رسم نمودیم.یافته ها: نمودارها و جداول نشان می دهند که، دوز جذبی و در نتیجه TER، در فانتوم آب، در هر عمق و هر میدانی با افزایش دما، زیاد می شود که این افزایش از دمای تقریبا 42oC به بالا تشدید می شود.نتیجه گیری: این مطالعه نشان می دهد که روش دمافزایی تغییرات ناگهانی در ساختار آب رخ و باعث افزایش دوز جذبی می شود.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1363

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 354 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2022
  • دوره: 

    12
  • شماره: 

    2
  • صفحات: 

    171-175
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    47
  • دانلود: 

    0
چکیده: 

The purpose of this study is to assess a rare case of fetal radiation absorbed dose here through 18 F-Fludeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) in early pregnancy (5-week-old fetus). The fetal absorbed dose due to the radiation emitted from the mother's body, the fetus self-dose, and the dose received from CT were computed. The 35-year-old patient, weighing 85 kg, was injected with 370 MBq of 18 F-FDG. Imaging started at 1 h with CT acquisition followed by PET imaging. The photon and positron self-dose was calculated by applying the Monte Carlo (MC) GATE (GEANT 4 Application for Tomographic Emission) code. The volume of absorbed dose from the mother's body organs and the absorbed dose from the CT were added to the self-dose to obtain the final dose. The volume of self-dose obtained through MC simulation for the fetus was 3. 3 × 10-2 mGy/MBq, of which 2. 97 × 10-2 mGy/MBq was associated with positrons and 0. 33 × 10-2 mGy/MBq was associated with photons. Biologically, the absorbed dose from CT, 7. 3 mGy, had to be added to the total dose. The absorbed dose by the fetus during early pregnancy was higher than the standard value of 2. 2 × 10-2 mGy/MBq (MIRD DER) because, during the examinations, the mother's bladder was full. This issue was a concern during updating standards.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 47

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2021
  • دوره: 

    19
  • شماره: 

    3
  • صفحات: 

    743-747
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    120
  • دانلود: 

    0
چکیده: 

Background: Nnewi town has undergone a marked increase in industrialization over the years. Considering the continuous disposal of automotive and hospital wastes in dumpsites within the town there is a need to ascertain the background radiation level of some of its dumpsites. Objective: To evaluate the level of background radiation in some selected dumpsites in Nnewi and compare the background radiation dose levels with the worldwide recommended average natural dose of 2. 4mSv/yr to humans. Methods: The levels of background radiation in these dumpsites were estimated using a well-calibrated International Medicom CRM-100 Digital Radiation Monitor (survey meter). A cross-sectional survey was adopted for this study. Following the standard procedure, the radiation monitor was held at a distance of 1. 0 meters above the ground and three readings are taken at each location and the mean recorded. The Annual Absorbed Dose Rate (ADR), Absorbed Dose Rate (AD) and the Annual Equivalent Dose Rate (AEDR) were calculated. Descriptive statistics were used to summarize the data using Statistical Package for Social Sciences SPSS version 20. Results: The mean of the calculated Annual Absorbed Dose Rates recorded at 21 and 24 meters was marginally greater than the accepted exposure rate for the public with the values of 1. 5 mSv/year respectively. At 12 and 27 meters, the values were 1. 5 mSv/year for Bank Road dumpsite respectively. Other distances were below the limit of 1mSv/year for the public and also below the dose limit of 20mSv/year for radiation workers as recommended by the ICRP. Conclusion: The radiation levels emitted from the study area were within permissible limits for the general population. Therefore there is little risk of instantaneous radiation hazard with an estimated safety zone at 6 meters from the dumpsites.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 120

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    2022
  • دوره: 

    19
  • شماره: 

    4
  • صفحات: 

    250-257
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    58
  • دانلود: 

    0
چکیده: 

Introduction: This study aimed to investigate the absorbed dose of scatter radiation in coronary angiography. Material and Methods: The scatter radiation dose was measured for 20 patients at four different heights (50, 100, 150, and 165 cm) from the floor. The spatial dose was measured by RTI Piranha r100b solid-state dose probe at different points around the patient in an actual clinical situation and with a phantom. Also, the measurement was repeated using a designed phantom in fluoroscopy and cine mode in posterior anterior (PA), left lateral (LLAT), left posterior oblique (LPO45°, ), right posterior oblique (RPO45°, ), and right-lateral (RLAT)projections. Organ-absorbed doses were normalized to dose area product (DAP). Results: The dose rate at different heights between the projections on the patient and the phantom as well as organ dose DAP conversion coefficients were different (p˂, 0. 05). It was found that the dose rate changes in fluoroscopic mode compared to cine mode are significantly different (p = 0. 001). The dose rate in cine mode is approximately four times that in fluoroscopy mode. The dose rate around the cardiologist's waist could be reduced by 37 –,43 % with a displacement of 20cm away. In this study, the effective dose rate received by the cardiologist’, s eyes was higher than those reported by ICRP. Conclusion: Taking a suitable projection could reduce the dose rate delivered to the angiography team. Further studies should be conducted about the effect of different projections with the same clinical use on dose distribution in coronary angiography to provide the best working conditions for physicians and staff.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 58

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

اطلاعات دوره: 
  • سال: 

    2022
  • دوره: 

    19
  • شماره: 

    -
  • صفحات: 

    0-0
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    7
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 7

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

CAKIR TAHIR | GUR A. | ARASOGLU A.

اطلاعات دوره: 
  • سال: 

    2012
  • دوره: 

    10
  • شماره: 

    3-4
  • صفحات: 

    157-164
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    341
  • دانلود: 

    0
چکیده: 

Background: Advances in radiation dosimetry concepts and the development of primary measurement standards based on absorbed dose to water over the last decades offer the possibility to calibrate ionisation chambers directly in terms of absorbed dose to water. The aim of this study is the investigation on utility of artificial body fluid (ABF) instead of water by comparing dosimetric measurements for radiotherapy between water and ABF which is more close to human tissue.Materials and Methods: The measurements were done using 60Co gamma source with a radiationfield sizes of 5×5, 10×10, 15×15, 20×20 and 25×25 cm2 at PTW Freiburg MP3 water phantom front surface. The comparisons of the dose measurements were obtained by using IAEA TRS-398 dosimetry protocols and Mephysto mc2 dose analyzer program. Percent depth dose (PDD), dose profiles and penumbras are compared for water and ABF.Results: When the results of the PDD for water and ABF were compared, the maximum difference was observed in big field sizes. The difference in penumbras was found 2.3 mm averagely for depth of maximum dose (dmax). In addition same differences were observed between water and ABF when the dose profiles were compared. It is found that PDD values taken for water are good agreed with PDD values published in British Journal of Radiology (BJR) Supplement 25.Conclusion: Since the ABF is more equivalent to human tissue than water, it is suggested that advanced dosimetric studies should be performed with ABF instead of water.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 341

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1382
  • دوره: 

    10
  • شماره: 

    45
  • صفحات: 

    75-82
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    960
  • دانلود: 

    0
چکیده: 

رادیوگرافی پانورامیک از روشهای تشخیصی مهم در بین پرتونگارهای دندان است که با توجه به کاربرد روزافزون آن، بررسی میزان دز دریافتی توسط اندامهای بحرانی در این رادیوگرافی ضروری به نظر می رسد. در این تحقیق دز جذبی چشمها، غدد پاروتید طرفین و سه ناحیه تیروییدبرای 40 بیمار بزرگسال در سیستم پارانومیک از نوع پلانمکا (Planmeca) به دست آمد. بدین منظور دوزیمترهای قرصی شکل لیتیم فلوراید (Lif) پس از کالیبره شدن، بر روی قسمتهای فوق قرار گرفته دز میانگین چشمها، غدد پاروتید وتیرویید در دو مرکز 1 و 2 به ترتیب به میزان: 10.0 ± 91.5 و 7.3 ± 84.3 ، 54.3± 2723 و 72.4 ± 2657 ، 28.4 ±1514 و 40.0 ±1461 میکروگری تعیین گردید. با بررسی نتایج معلوم شد که بین دزهای دریافتی دو چشم، غدد پاروتید دوطرف و سه ناحیه تیرویید اختلاف معناداری وجود ندارد (P>0.05) این یافته با نحوه عملکرد سیستم پانورامیک قابل انتظار بود. از طرف دیگر با مقایسه نتایج مشاهده می شود که بین دزهای هر سه اندام در دو مرکز اختلاف معناداری وجود دارد (P<0.05) که به نظر می رسد به علت بارکاری بیشتر مرکز 1 و عدم انجام کالیبراسیون مجدد این سیستم ها باشد. همچنین مقادیر حاصل با حد دز تعیین شده برای چشم و تخمین های خطر بروز ناهنجاری در اندام ها که توسط سازمانهای بین المللی حفاظت پرتوی نظیر کمیسیون بین المللی حفاظت پرتوی (International Commission on Rediological Protection(ICRP) اعلام شده، اختلاف قابل ملاحظه ای را نشان می دهد. لازم به ذکر است اگر چه دزجذبی اندامها در رادیوگرافی پانورامیک در سطح پایینی قرار دارد، اما طبق اص به هر میزان کم که عقلا قابل دستیابی است (As Low As Reasonably) در حفاظت پرتوی و با توجه به احتمال تکرار این آزمایش در فواصل زمانی کوتاه، باید برخی راهکارها مانند انجام کالیبراسیون سیستمهای پانورامیک در دوره های مشخص را برای پایینتر نگهداشتن معقول دز این نوع آزمایش در نظر داشت.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 960

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button