مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

863
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EVALUATION THE EFFECT OF UNCERTAINTIES CAUSED BY SOIL MOISTURE ADJUSTED FACTOR ON ACTUAL EVAPOTRANSPIRATION PREDICTION

Pages

  454-465

Abstract

 Since a significant amount of precipitation in the agricultural watersheds is used by evapotranspiration, so this parameter plays an important role in water budget and water resources management. Therefore, accurate estimation of this component is very important. SEBAL (Surface ENERGY BALANCE Algorithm for Land) belongs to the methods of estimating the actual evapotranspiration (ETact) which is based on remote sensing technique. In the structure of this algorithm several indices and empirical coefficients are used, each of them is effective for estimating actual evapotranspiration. In this study the effect of the uncertainty caused by the soil adjusted vegetation index (SAVI) values in the form of SEBAL algorithm was investigated on ETact prediction on the part of Neyshabour watershed. To determine the optimize value of SAVI, 2013 and 2014 MODIS SATELLITE IMAGES were used and the effect of SAVI values uncertainty on ETact prediction was discussed in 2014. Comparison between estimated values and MICROLYSIMETER measurements of ETact in the discussed polygon showed that the minimum and maximum error of ETact estimation has been obtained for the amount of 0.2 (R2=0.99, RMSE=0.07) and 1 (R2=0.12, RMSE=0.6) for L coefficient in the SAVI index structure. The results of t-test also showed the significant differences at 95% (p<0.05) between measured and predicted values of ETact, using the whole range of L coefficient, except 0.2.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MOAZENZADEH, R.. (2016). EVALUATION THE EFFECT OF UNCERTAINTIES CAUSED BY SOIL MOISTURE ADJUSTED FACTOR ON ACTUAL EVAPOTRANSPIRATION PREDICTION. IRANIAN JOURNAL OF IRRIGATION AND DRAINAGE, 10(4 ), 454-465. SID. https://sid.ir/paper/131587/en

    Vancouver: Copy

    MOAZENZADEH R.. EVALUATION THE EFFECT OF UNCERTAINTIES CAUSED BY SOIL MOISTURE ADJUSTED FACTOR ON ACTUAL EVAPOTRANSPIRATION PREDICTION. IRANIAN JOURNAL OF IRRIGATION AND DRAINAGE[Internet]. 2016;10(4 ):454-465. Available from: https://sid.ir/paper/131587/en

    IEEE: Copy

    R. MOAZENZADEH, “EVALUATION THE EFFECT OF UNCERTAINTIES CAUSED BY SOIL MOISTURE ADJUSTED FACTOR ON ACTUAL EVAPOTRANSPIRATION PREDICTION,” IRANIAN JOURNAL OF IRRIGATION AND DRAINAGE, vol. 10, no. 4 , pp. 454–465, 2016, [Online]. Available: https://sid.ir/paper/131587/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button