مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

713
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EFFECT OF SUBMERGED VANES ON INTAKE RATIO AND WATER SURFACEPROFILE AT 90O DIVERSION

Pages

  104-114

Abstract

 Submerged vanes are hydraulic structures for sediment control at intake entrance. In this paper, hydraulic performance of these structures within high Froude Numbers was studied experimentally. A total of 24 experiments were carried out in a flume with 17m length, 40 cm width and 900 diversion angle with and without using a set of SUBMERGED VANES. Effects of angle variations of SUBMERGED VANES and discharge on INTAKE RATIO and WATER SURFACE PROFILEs near intake in main channel were investigated. The results showed that application of SUBMERGED VANES, regardless of their angles, cause the increase of water surface elevations near upstream vanes when flow parameter was 169 (30 lps, sub-critical flow) in main channel. Also, due to their relative high angle, an increase in water surface elevation was observed near upstream of 25o angle vanes when flow rate was 339 (60 lps, super-critical flow) in main channel. The experimental results indicated that in supercritical flow a sudden increase in flow depth occurred downstream close to intake when the SUBMERGED VANES were not used. Compared to the condition with no vanes, the results showed that the application of 25o angle SUBMERGED VANES causes an increase in INTAKE RATIO. However, a reduction in INTAKE RATIO was observed in the case of 150 angle vanes and no change was observed in INTAKE RATIO when the angle was 20o.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    HASANPOUR, F., AYOUBZADEH, SEYED ALI, GHODSIAN, MASOUD, & MOHAMMAD VALI SAMANI, J.. (2008). EFFECT OF SUBMERGED VANES ON INTAKE RATIO AND WATER SURFACEPROFILE AT 90O DIVERSION. PAJOUHESH-VA-SAZANDEGI, 20(4 (77 IN NATURAL RESOURCES)), 104-114. SID. https://sid.ir/paper/19874/en

    Vancouver: Copy

    HASANPOUR F., AYOUBZADEH SEYED ALI, GHODSIAN MASOUD, MOHAMMAD VALI SAMANI J.. EFFECT OF SUBMERGED VANES ON INTAKE RATIO AND WATER SURFACEPROFILE AT 90O DIVERSION. PAJOUHESH-VA-SAZANDEGI[Internet]. 2008;20(4 (77 IN NATURAL RESOURCES)):104-114. Available from: https://sid.ir/paper/19874/en

    IEEE: Copy

    F. HASANPOUR, SEYED ALI AYOUBZADEH, MASOUD GHODSIAN, and J. MOHAMMAD VALI SAMANI, “EFFECT OF SUBMERGED VANES ON INTAKE RATIO AND WATER SURFACEPROFILE AT 90O DIVERSION,” PAJOUHESH-VA-SAZANDEGI, vol. 20, no. 4 (77 IN NATURAL RESOURCES), pp. 104–114, 2008, [Online]. Available: https://sid.ir/paper/19874/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button