مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

55
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

26
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

The Study of Fatigue Behavior of Glass Fiber Reinforced epoxy(GFRP) Composite Under Different Stress Levels

Author(s)

 Moghaddas Mousavi Zadeh Alireza | Zabett Ahad | Sahebian saghi ُSamane | Issue Writer Certificate 

Pages

  1-12

Abstract

 The aim of this study is to investigate the Fatigue behavior of GFRP Composite with biaxial fiber orientation [0,90] under different stress levels. First, the tensile test was performed and the UTS value was 420 MPa. Then, Fatigue test was performed at 4 stress levels of 70, 50, 42 and 35% of UTS. Fatigue results had acceptable dispersion and the fitting curve on the data also matched well. Finally, the Fatigue failure structures of 70 and 35% of UTS samples, using scanning electron microscopy (SEM) were evaluated. The results showed that in both 70 and 35% samples, the mechanism of pull out fibers was obsvered but its intensity was higher in 35% sample. Also in the 35% sample, significant distortion was observed which was absent in the 70% sample. On the other hand, the brittle failure of matrix was more pronounced in the 70% sample than in the 35% sample. This can be related to the increase of the matrix softness due to the application of cyclic load.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button