مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

711
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

SEISMIC PERFORMANCE OF SELF-CENTERING MOMENT RESISTING CONNECTIONS WITH BOTTOM FLANGE FRICTION DEVICES (BFFD)

Pages

  81-93

Abstract

 Recently self-centric moment resisting connections have been introduced as alternative welded moment resisting connections. These connections are comparing of post tensioned strands and energy dissipater parts. In construction of connection the high strength strands have been post tensioned and because of the post tensioned forces during earthquake period, the structure returns to the pre earthquake condition with less damage in comparison with usual moment resisting structures. One of the energy dissipater devices of these systems is bottom flange friction device (BFFD). In this paper, firstly the behavior of connection in 6 story 4 bay building have been verified with literature which OPENSEES software is used for this purpose. Then nonlinear dynamic and static analyses have been performed. In this study the number of POST-TENSIONED STRANDS, optimum force of strands, arrangement of strands in stories and SHAPE MEMORY ALLOY materials effect on strand’s behavior have been evaluated. The results shows increment of strands to 40 improves the behavior of connection and the increasing of post-tensioned forces up to determined value causes the improvement of connection behavior.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    GHOBADI, M.S., KARGAR NAJAFI, M., & AHMADI JAZANI, R.. (2015). SEISMIC PERFORMANCE OF SELF-CENTERING MOMENT RESISTING CONNECTIONS WITH BOTTOM FLANGE FRICTION DEVICES (BFFD). STRUCTURE AND STEEL, 10(16), 81-93. SID. https://sid.ir/paper/136674/en

    Vancouver: Copy

    GHOBADI M.S., KARGAR NAJAFI M., AHMADI JAZANI R.. SEISMIC PERFORMANCE OF SELF-CENTERING MOMENT RESISTING CONNECTIONS WITH BOTTOM FLANGE FRICTION DEVICES (BFFD). STRUCTURE AND STEEL[Internet]. 2015;10(16):81-93. Available from: https://sid.ir/paper/136674/en

    IEEE: Copy

    M.S. GHOBADI, M. KARGAR NAJAFI, and R. AHMADI JAZANI, “SEISMIC PERFORMANCE OF SELF-CENTERING MOMENT RESISTING CONNECTIONS WITH BOTTOM FLANGE FRICTION DEVICES (BFFD),” STRUCTURE AND STEEL, vol. 10, no. 16, pp. 81–93, 2015, [Online]. Available: https://sid.ir/paper/136674/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button