مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

14
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

3
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Experimental Study the Performance of Bottom Cavitator in Water Conveyance Tunnel and its Effect on Separation Length

Pages

  56-75

Abstract

 Cavitation is one of the most common and destructive causes of spillways and water conveyance tunnels. One of the most effective ways to prevent the Cavitation is to aerate the current, provide the pressure and prevent excessive suction. The longer is the separation length downstream of the air entrance to flow, the more efficiency of Cavitator. Conventional types of aerators (Cavitators) in hydraulic structures including ramps, steps, grooves, and their combinations. In this research, the performance of 19 Cavitators with different geometries in a pressurized flow inside a box tunnel, for 5 discharges with/without Aeration were investigated. All experiments were performed for 3 times to validate the experimental results and reduce the experimental errors. Statistical analysis of the experimental results showed that the type of Cavitator had considerable effects on the separation length. In spite of the positive effects of ramp height and discharge on separation length, the angle of ramp, step height, and groove depth had non-significant effects on separation length. Finally, two combined aerators were proposed, which in practice had better results in comparison with conventional aerators in hydraulic structures.

Cites

  • No record.
  • References

  • No record.
  • Cite

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button