مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

15
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Investigation of Steel moment Frame with frictional-rotational dampers by endurance time method

Pages

  40-61

Abstract

 The most comprehensive analysis methods are non-linear methods that require a lot of calculations. In this research, the Endurance Time method is used, that is a new dynamic method in which the need for calculations is reduced. In the Endurance Time method, the structures are subjected to specially designed acceleration functions and their response at different performance levels is estimated by each of the unit response history analyses, thus, significantly reducing the required computational demand. The design of rotational friction dampers in the studied structures was done based on the seismic Performance index by Endurance Time method, and the sliding force of these dampers was uniformly distributed in the structure. The results of this research for two structures of 3 and 9 floors showed that the shear of the base is between 60 and 100%, as expected, considering that the structure was a moment frame at the beginning and had a different Target time, and then braces were added to it. Increased. Due to the addition of the damper to the system, taking into account the relative increase in input energy, as expected, the amount of depreciated energy is between 10 and 97%. In relation to the study of drift, the reduction of the values in the floors was high, which was reported from 5 to more than 50% according to the results

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button