مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

597
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

443
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

BASE SHEAR COEFFICIENTS AND DISPLACEMENT AMPLIFICATION FACTORS OF TALL BUILDINGS WITH TUBULAR AND OUTRIGGER BRACING SYSTEMS ON FLEXIBLE SOIL

Pages

  723-732

Abstract

 Currently, the FRAMED-tube and outrigger-braced systems are known as two conventional load bearing systems in TALL BUILDINGS. These structural systems can be used in TALL BUILDINGS with high efficiency to provide the necessary lateral stiffness and strength against lateral forces due to earthquakes or strong storms. On the other hand, increasing the stiffness of these structures augments the relative importance of flexibility of the underlying soil and the resulting added displacements. This paper aims to study the seismic behavior of FRAMED-tube and outrigger-braced TALL BUILDINGS on FLEXIBLE SOIL in comparison to a rigid base. For this purpose, a range of 10 to 50-storey steel buildings with both structural systems on flexible and rigid bases are analyzed dynamically and the maximum base shear and lateral roof displacement are calculated. Also for comparing the benefit of each system, the total weight of steel used per system in each case is calculated. Results indicated that the design spectrum of Standard 2800 overestimates the response of the studied systems. Overall, the tubular system more economically provides the necessary stiffness and strength of the building system.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    BEHNAMFAR, F., & MOHAJERI, A.H.. (2018). BASE SHEAR COEFFICIENTS AND DISPLACEMENT AMPLIFICATION FACTORS OF TALL BUILDINGS WITH TUBULAR AND OUTRIGGER BRACING SYSTEMS ON FLEXIBLE SOIL. AMIRKABIR JOURNAL OF CIVIL ENGINEERING (AMIRKABIR), 49(4 ), 723-732. SID. https://sid.ir/paper/165604/en

    Vancouver: Copy

    BEHNAMFAR F., MOHAJERI A.H.. BASE SHEAR COEFFICIENTS AND DISPLACEMENT AMPLIFICATION FACTORS OF TALL BUILDINGS WITH TUBULAR AND OUTRIGGER BRACING SYSTEMS ON FLEXIBLE SOIL. AMIRKABIR JOURNAL OF CIVIL ENGINEERING (AMIRKABIR)[Internet]. 2018;49(4 ):723-732. Available from: https://sid.ir/paper/165604/en

    IEEE: Copy

    F. BEHNAMFAR, and A.H. MOHAJERI, “BASE SHEAR COEFFICIENTS AND DISPLACEMENT AMPLIFICATION FACTORS OF TALL BUILDINGS WITH TUBULAR AND OUTRIGGER BRACING SYSTEMS ON FLEXIBLE SOIL,” AMIRKABIR JOURNAL OF CIVIL ENGINEERING (AMIRKABIR), vol. 49, no. 4 , pp. 723–732, 2018, [Online]. Available: https://sid.ir/paper/165604/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button