مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,513
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Fabrication of Qualitative Uranium Indicator and Quantitative Evaluation of the Results by Image Processing Method using MATLAB Software

Pages

  67-78

Abstract

 In the present study, the Uranium qualitative Detector package containing Arsenazo and Bromo-PADAP Indicators was designed; and also, the metalic ion Detector package using Dithizone Indicator was built for detection and determination of some ionic interference via Uranium colorimetric method. The obtained results indicated that the detection limits of Uranium ions were equal to 50 ppm and 20 ppm respectively using Detectors containing Arsenazo and Bromo-PADAP Indicators. In the acidic media (pH=5), the Uranium Detectors had good detection performance. The metalic ion Detector detected ions such as cobalt (II), copper (II), nickel (II), zinc (II), cadmium and silver until the detection limit 50 ppm. Arsenazo Detector was superior to Bromo-PADAP Detector for detection of Uranium since it prevented any ionic interference even in very high concentrations which with absorbtion of a solution containing Uranium ion, Arsenazo and Bromo-PADAP Detectors in the presence masking agents in buffer solution produced miry green and purple colors respectively. While the operation time for Uranium ion detection in the presence of Arsenazo and Bromo-PADAP Detectors was3 minutes and 1 minute respectively. Also, the quantitative evaluations based on image processing methods using MATLAB software show that the experimental results are consistent with the evaluation results.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KHAJEH AMIRI, A.R., SHOJAEI, J., & Faghani, Gh.R.. (2019). Fabrication of Qualitative Uranium Indicator and Quantitative Evaluation of the Results by Image Processing Method using MATLAB Software. (JOURNAL OF ADVANCED DEFENCE SCIENCE AND TECHNOLOGY) JOURNAL OF PASSIVE DEFENCE SCIENCE AND TECHNOLOGY, 10(1 ), 67-78. SID. https://sid.ir/paper/167510/en

    Vancouver: Copy

    KHAJEH AMIRI A.R., SHOJAEI J., Faghani Gh.R.. Fabrication of Qualitative Uranium Indicator and Quantitative Evaluation of the Results by Image Processing Method using MATLAB Software. (JOURNAL OF ADVANCED DEFENCE SCIENCE AND TECHNOLOGY) JOURNAL OF PASSIVE DEFENCE SCIENCE AND TECHNOLOGY[Internet]. 2019;10(1 ):67-78. Available from: https://sid.ir/paper/167510/en

    IEEE: Copy

    A.R. KHAJEH AMIRI, J. SHOJAEI, and Gh.R. Faghani, “Fabrication of Qualitative Uranium Indicator and Quantitative Evaluation of the Results by Image Processing Method using MATLAB Software,” (JOURNAL OF ADVANCED DEFENCE SCIENCE AND TECHNOLOGY) JOURNAL OF PASSIVE DEFENCE SCIENCE AND TECHNOLOGY, vol. 10, no. 1 , pp. 67–78, 2019, [Online]. Available: https://sid.ir/paper/167510/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button