مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

932
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

NUMERICAL SIMULATION OF JUNCTION ANGLE AND DISCHARGE RATIO ON SEPARATION ZONE DIMENSIONS AT OPEN JUNCTION CHANNELS

Author(s)

GOHARI S. | Issue Writer Certificate 

Pages

  69-78

Abstract

 The confluence of two streams creates a complex flow which accelerates downstream. In a junction area, the SEPARATION ZONE is developed in the main channel. By decreasing the longitudinal velocity in the SEPARATION ZONE the sedimentation and blocking of section are increased. In this research, the SEPARATION ZONE dimensions for the junction 30o, 45o, 60o and 90o, and DISCHARGE RATIOs are simulated by using the FLUENT software. The Volume of Fluid (VOF) scheme and the RSM turbulence model were used for numerical simulation. The results showed that reducing the JUNCTION ANGLE leads to decreasing SEPARATION ZONE dimensions at the junction in the main channel. Results also showed that the model simulated the experimental velocity values by an average of 4 percent accuracy. The maximum width of SEPARATION ZONE is about 50% of the main channel width occurred at an angle of 90o of junction channel, and the minimum dimensions of the flow SEPARATION ZONE near zero and occurred at the JUNCTION ANGLE of 30o. Furthermore, increasing JUNCTION ANGLE widens the SEPARATION ZONE dimensions. Maximum and minimum SEPARATION ZONE dimensions occurred at 90 and 30 degree of junction, respectively. Further changes in the DISCHARGE RATIO have a great effect on SEPARATION ZONE dimensions and disappear when the DISCHARGE RATIO is decreased. Decreasing JUNCTION ANGLE and increasing the DISCHARGE RATIO simultaneously, can reduce the SEPARATION ZONE dimensions and therefore, the problems developed the junction.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    GOHARI, S.. (2015). NUMERICAL SIMULATION OF JUNCTION ANGLE AND DISCHARGE RATIO ON SEPARATION ZONE DIMENSIONS AT OPEN JUNCTION CHANNELS. WATER ENGINEERING, 8(24), 69-78. SID. https://sid.ir/paper/169350/en

    Vancouver: Copy

    GOHARI S.. NUMERICAL SIMULATION OF JUNCTION ANGLE AND DISCHARGE RATIO ON SEPARATION ZONE DIMENSIONS AT OPEN JUNCTION CHANNELS. WATER ENGINEERING[Internet]. 2015;8(24):69-78. Available from: https://sid.ir/paper/169350/en

    IEEE: Copy

    S. GOHARI, “NUMERICAL SIMULATION OF JUNCTION ANGLE AND DISCHARGE RATIO ON SEPARATION ZONE DIMENSIONS AT OPEN JUNCTION CHANNELS,” WATER ENGINEERING, vol. 8, no. 24, pp. 69–78, 2015, [Online]. Available: https://sid.ir/paper/169350/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top