مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,037
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

INVESTIGATION OF A DIRECT-EXPANSION GROUND SOURCE HEAT PUMP USING CARBON DIOXIDE

Pages

  433-443

Abstract

 This paper presents a steady state simulation model to analyze a DIRECT EXPANSION GROUND SOURCE HEAT PUMP that uses CARBON DIOXIDE as refrigerant in a TRANSCRITICAL cycle. The analysis considers PRESSURE DROP characteristic in heat exchangers of the system. The present numerical model has been developed to examine the system in different operating conditions in two separate cases. These cases include constant evaporator loop length and specific heating load. Then model evaluates the system based on coefficient of performance (COP) and heating capacity in the first case and COP and evaporator loop length in the second case. To examine the performance of the system, a parametric study is performed to investigate the effect of different parameters such as difference between soil temperature and evaporator outlet temperature, compressor speed, water inlet temperature, water mass flow rate, area ratio heat exchanger and soil temperature. In both studies, it can be concluded that in a specific temperature difference of the difference between soil temperature and the outlet temperature of the evaporator, there is a maximum value for COP. Also, increasing the compressor speed and the temperature of inlet water to the gas cooler is accompanied with the reduction of COP. Increasing the mass flow rate of inlet water to the gas cooler leads to increase in COP. The results of this study include heating capacity, COP and ground heat exchanger loop length can be used for design and optimization of a DIRECT EXPANSION GROUND SOURCE HEAT PUMP.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    GHAZIZADE AHSAEE, HOSSEIN, & AMERI, MEHRAN. (2017). INVESTIGATION OF A DIRECT-EXPANSION GROUND SOURCE HEAT PUMP USING CARBON DIOXIDE. MODARES MECHANICAL ENGINEERING, 17(6 ), 433-443. SID. https://sid.ir/paper/179262/en

    Vancouver: Copy

    GHAZIZADE AHSAEE HOSSEIN, AMERI MEHRAN. INVESTIGATION OF A DIRECT-EXPANSION GROUND SOURCE HEAT PUMP USING CARBON DIOXIDE. MODARES MECHANICAL ENGINEERING[Internet]. 2017;17(6 ):433-443. Available from: https://sid.ir/paper/179262/en

    IEEE: Copy

    HOSSEIN GHAZIZADE AHSAEE, and MEHRAN AMERI, “INVESTIGATION OF A DIRECT-EXPANSION GROUND SOURCE HEAT PUMP USING CARBON DIOXIDE,” MODARES MECHANICAL ENGINEERING, vol. 17, no. 6 , pp. 433–443, 2017, [Online]. Available: https://sid.ir/paper/179262/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button