مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

717
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THREE-DIMENSIONAL MODELING OF A DEW-POINT EVAPORATIVE COOLER USING A MODIFIED BOUNDARY CONDITION AND CONSIDERING EFFECTS OF CHANNELS’ ENTRANCE REGIONS

Pages

  68-78

Abstract

 This paper presents a NUMERICAL MODELING of dew-point counter-flow indirect evaporative coolers as a potential alternative to the conventional cooling systems. Unlike the conventional method of assuming constant surface heat (mass) flux or constant surface temperature boundary condition on the separating wall, the present article calculated real boundary conditions. Real boundary conditions were obtained by simultaneous solving of momentum, energy and MASS TRANSFER equations of the two flows coupled on the wall. Calculating real boundary conditions led to a real distribution of humidity ratio and temperature on the separating wall where at each point, the summation of heat fluxes from air streams in adjacent channels is equal to the latent heat of evaporation at that point. Moreover, the model accuracy was increased through considering hydrodynamic and thermal developing flows of two air streams. The model predicted supply air temperature under different conditions, and the results were compared against experimental data as well as previous numerical models. It was shown that the maximum deviation of the supply air temperature was under ±3.3%. Then, a parametric analysis was conducted that studies the effects of the inlet air velocity, channel gap, channel length and returned air ratio on the supply air temperature, dew-point effectiveness, cooling capacity and pressure drop. The results indicated that increasing channel length and returned air ratio, and reducing channel gap and inlet air velocity improved the dew-point effectiveness but increased the initial cost and pressure drop and decreased the cooling capacity.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    JAFARIAN, HAMOON, SAYYAADI, HOSEYN, & TORABI, FARSCHAD. (2017). THREE-DIMENSIONAL MODELING OF A DEW-POINT EVAPORATIVE COOLER USING A MODIFIED BOUNDARY CONDITION AND CONSIDERING EFFECTS OF CHANNELS’ ENTRANCE REGIONS. MODARES MECHANICAL ENGINEERING, 17(7 ), 68-78. SID. https://sid.ir/paper/179332/en

    Vancouver: Copy

    JAFARIAN HAMOON, SAYYAADI HOSEYN, TORABI FARSCHAD. THREE-DIMENSIONAL MODELING OF A DEW-POINT EVAPORATIVE COOLER USING A MODIFIED BOUNDARY CONDITION AND CONSIDERING EFFECTS OF CHANNELS’ ENTRANCE REGIONS. MODARES MECHANICAL ENGINEERING[Internet]. 2017;17(7 ):68-78. Available from: https://sid.ir/paper/179332/en

    IEEE: Copy

    HAMOON JAFARIAN, HOSEYN SAYYAADI, and FARSCHAD TORABI, “THREE-DIMENSIONAL MODELING OF A DEW-POINT EVAPORATIVE COOLER USING A MODIFIED BOUNDARY CONDITION AND CONSIDERING EFFECTS OF CHANNELS’ ENTRANCE REGIONS,” MODARES MECHANICAL ENGINEERING, vol. 17, no. 7 , pp. 68–78, 2017, [Online]. Available: https://sid.ir/paper/179332/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top