مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

996
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Modified Electrical Conductivity Test Method for Evaluation Concrete Chloride Ion Permeability

Pages

  77-92

Abstract

 Standard test method for bulk electrical Conductivity (ASTM C1760) provides a rapid indication of the Concrete’ s resistance to the penetration of chloride ions by diffusion. In this paper a new approach for assessing the bulk electrical Conductivity of saturated specimens of hardened Concrete is presented. The test involves saturating Concrete specimens with a 5 M NaCl solution before measuring the Conductivity of the samples. By saturating specimens with a highly conductive solution, they showed virtually the same Pore Solution Conductivity. Different Concrete samples yield different Conductivity primarily due to differences in their pore structure. The feasibility of the method has been demonstrated by testing different Concrete mixtures consisting ordinary and blended cement of silica fume (SF) and calcined perlite powder (CPP). Two standard test methods of RCPT (ASTM C1202) and Bulk Conductivity (ASTM C1760) were also applied to all of the samples. The results show that for Concretes containing SF and CPP, the proposed method is less sensitive towards the variations in the Pore Solution Conductivity in comparison with RCPT and Bulk Conductivity tests. It seems that this method is suitable for the assessment of the performance and durability of different Concretes containing supplementary cementitious materials.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    PILVAR, A.R., RAMEZANIANPOUR, A.A., & RAJAEI, H.. (2018). Modified Electrical Conductivity Test Method for Evaluation Concrete Chloride Ion Permeability. JOURNAL OF CIVIL ENGINEERING (JOURNAL OF SCHOOL OF ENGINEERING), 30(2 ), 77-92. SID. https://sid.ir/paper/195922/en

    Vancouver: Copy

    PILVAR A.R., RAMEZANIANPOUR A.A., RAJAEI H.. Modified Electrical Conductivity Test Method for Evaluation Concrete Chloride Ion Permeability. JOURNAL OF CIVIL ENGINEERING (JOURNAL OF SCHOOL OF ENGINEERING)[Internet]. 2018;30(2 ):77-92. Available from: https://sid.ir/paper/195922/en

    IEEE: Copy

    A.R. PILVAR, A.A. RAMEZANIANPOUR, and H. RAJAEI, “Modified Electrical Conductivity Test Method for Evaluation Concrete Chloride Ion Permeability,” JOURNAL OF CIVIL ENGINEERING (JOURNAL OF SCHOOL OF ENGINEERING), vol. 30, no. 2 , pp. 77–92, 2018, [Online]. Available: https://sid.ir/paper/195922/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button