مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

818
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

491
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

An ANFIS-Based Method for Identification Switched Capacitor Bank Location in Distribution Systems

Pages

  41-50

Keywords

Fuzzy Inference System (ANFIS) capacitor switching power distribution power quality wavelet transformsQ2

Abstract

 In this paper, a new method based on Adaptive Neuro-Fuzzy Inference System (ANFIS) is proposed for locating the switched capacitor banks in distribution systems. To train the proposed ANFIS model, an index based on current transient is introduced, which is calculated either offline by using data or online by real time simulation. The proposed method uses only current transient waveforms, immediately before and after the switching instant. Since only the current signal is used which is available in several locations, the method is simple and can be applied online. The method uses wavelet to determine the capacitor switching instant, which is needed for the ANFIS model to locate the switching capacitor. The method is simulated using PSCAD. Through various simulations, it is shown that other power quality disturbances such as voltage dip, unbalances and harmonics cannot disturb the method. Moreover, the size and connection type of the capacitor bank do not affect the method accuracy. The proposed algorithm is validated by simulating the IEEE 13-bus distribution system. According to the simulation results, the method is reliable enough to be applied to real systems.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MADANI, SEYED MOHAMMAD, & SADEGHI, RAMTIN. (2019). An ANFIS-Based Method for Identification Switched Capacitor Bank Location in Distribution Systems. COMPUTATIONAL INTELLIGENCE IN ELECTRICAL ENGINEERING (INTELLIGENT SYSTEMS IN ELECTRICAL ENGINEERING), 10(1 ), 41-50. SID. https://sid.ir/paper/202993/en

    Vancouver: Copy

    MADANI SEYED MOHAMMAD, SADEGHI RAMTIN. An ANFIS-Based Method for Identification Switched Capacitor Bank Location in Distribution Systems. COMPUTATIONAL INTELLIGENCE IN ELECTRICAL ENGINEERING (INTELLIGENT SYSTEMS IN ELECTRICAL ENGINEERING)[Internet]. 2019;10(1 ):41-50. Available from: https://sid.ir/paper/202993/en

    IEEE: Copy

    SEYED MOHAMMAD MADANI, and RAMTIN SADEGHI, “An ANFIS-Based Method for Identification Switched Capacitor Bank Location in Distribution Systems,” COMPUTATIONAL INTELLIGENCE IN ELECTRICAL ENGINEERING (INTELLIGENT SYSTEMS IN ELECTRICAL ENGINEERING), vol. 10, no. 1 , pp. 41–50, 2019, [Online]. Available: https://sid.ir/paper/202993/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button