مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

731
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMBINED OPERATION OF DC ISOLATED DISTRIBUTION AND PV SYSTEMS FOR SUPPLYING UNBALANCED AC LOADS

Pages

  41-51

Abstract

 This paper presents a Loop DC isolated network which is fed by photovoltaic (PV) renewable sources to supply unbalanced AC loads. The battery energy storage bank has been connected to the DC network via DC/DC converter called storage converter to control the network voltage and optimize the operation of the PV generation units. The PV units are connected to the DC network via its own DC/DC converter called, PV converter to ensure the required power flow. The unbalanced AC loads are connected to the DC network via its own DC/AC converter called, load converter without transformer. This paper proposes a novel control strategy for storage converter which has a DC voltage droop regulator. Also a novel control system based on Clark and Park rotating frame has been proposed for load converters. In this paper, the proposed operation method is demonstrated by simulation of power transfer between PV units, unbalanced AC loads and battery units. The simulation results based on PSCAD/EMTDC software show that DC isolated distribution system including PV units can provide the BALANCED VOLTAGEs to supply unbalanced AC loads.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    NOROOZIAN, REZA, & MOHAMMADI, H.. (2016). COMBINED OPERATION OF DC ISOLATED DISTRIBUTION AND PV SYSTEMS FOR SUPPLYING UNBALANCED AC LOADS. COMPUTATIONAL INTELLIGENCE IN ELECTRICAL ENGINEERING (INTELLIGENT SYSTEMS IN ELECTRICAL ENGINEERING), 7(2), 41-51. SID. https://sid.ir/paper/203013/en

    Vancouver: Copy

    NOROOZIAN REZA, MOHAMMADI H.. COMBINED OPERATION OF DC ISOLATED DISTRIBUTION AND PV SYSTEMS FOR SUPPLYING UNBALANCED AC LOADS. COMPUTATIONAL INTELLIGENCE IN ELECTRICAL ENGINEERING (INTELLIGENT SYSTEMS IN ELECTRICAL ENGINEERING)[Internet]. 2016;7(2):41-51. Available from: https://sid.ir/paper/203013/en

    IEEE: Copy

    REZA NOROOZIAN, and H. MOHAMMADI, “COMBINED OPERATION OF DC ISOLATED DISTRIBUTION AND PV SYSTEMS FOR SUPPLYING UNBALANCED AC LOADS,” COMPUTATIONAL INTELLIGENCE IN ELECTRICAL ENGINEERING (INTELLIGENT SYSTEMS IN ELECTRICAL ENGINEERING), vol. 7, no. 2, pp. 41–51, 2016, [Online]. Available: https://sid.ir/paper/203013/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button