مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

491
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Effects of Inlet Air diffusers’ Arrangementon the performance of Displacement ventilation system based on thermal comfort conditions, indoor air quality and Energy consumption in a dense occupancy environment

Pages

  21-30

Abstract

 In dense occupancy spaces, providing the proper conditions especially as Indoor air quality is very important. On the other hand, in most air distribution systems, the ventilation performance and energy saving parameters are greatly influenced by the arrangements of supply diffuser positions. Therefore, in this study, the effects of supply diffuser positions on Thermal comfort, Indoor air quality and Energy consumption in an amphitheater have been investigated. For this issue, a small amphitheater with 50 occupants has been modeled under the conditions that the linear air inlet diffusers located in four situations. The results indicate that the Displacement ventilation can provide the proper conditions. However, by changing the location of supply diffuser positions, IAQ and occupants comfort can be improved. For example, for the inlet diffusers are located vertically on the floor, relative ventilation effectiveness is improved about 20% and CO2concentration is decreased about10% in comparison with the other cases.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Afzalian, M., & Zolfaghari, S. A. R.. (2019). Effects of Inlet Air diffusers’ Arrangementon the performance of Displacement ventilation system based on thermal comfort conditions, indoor air quality and Energy consumption in a dense occupancy environment. JOURNAL OF MECHANICAL ENGINEERING, 49(1 (86) ), 21-30. SID. https://sid.ir/paper/269962/en

    Vancouver: Copy

    Afzalian M., Zolfaghari S. A. R.. Effects of Inlet Air diffusers’ Arrangementon the performance of Displacement ventilation system based on thermal comfort conditions, indoor air quality and Energy consumption in a dense occupancy environment. JOURNAL OF MECHANICAL ENGINEERING[Internet]. 2019;49(1 (86) ):21-30. Available from: https://sid.ir/paper/269962/en

    IEEE: Copy

    M. Afzalian, and S. A. R. Zolfaghari, “Effects of Inlet Air diffusers’ Arrangementon the performance of Displacement ventilation system based on thermal comfort conditions, indoor air quality and Energy consumption in a dense occupancy environment,” JOURNAL OF MECHANICAL ENGINEERING, vol. 49, no. 1 (86) , pp. 21–30, 2019, [Online]. Available: https://sid.ir/paper/269962/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button