مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

614
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Impact of Central Courtyard Proportions on Passive Cooling Potential in Hot and Humid Regions (Case Study: Single-story Buildings in Bandar Abbas)

Pages

  137-152

Abstract

 Aims: The central Courtyard can play an important role in reducing Energy consumption, increasing Shading, enhancing the flow of passage and creating evaporative Cooling in windphil buildings. This paper seeks to examine the role of central Courtyard proportions in the amount of Shading, radiant Energy received, Cooling load and natural Ventilation potential. Methods: The research method in this research is a descriptive-analytical one in which the software of Design builder 6. 1. 2. 009, Computational Fluid Dynamics (CFD), and Ecotect 2011 were applied to investigate the effect of central yard width change on wind flow pattern, Shading pattern and the amount of radiant Energy received and the calculation Cooling load of Windphil Architecture. Findings: Comparing U-shaped quadruple buildings with a central Courtyard with a fixed volume-to surface ratio, the 4-meter-wide Courtyard building model is the best option. Changing the width of central Courtyard from 4 to 10 meters resulted in a %13 increase in Cooling load and a %10 decrease in shaded areas. However, increasing the width of the Courtyard from 4 to 6 meters resulted in a speed reduction of 18. 75% and a change of width from 6 to 10 meters lead to a 6% increase in flow rate. Conclusion: Increasing the width of the central Courtyard degrades the passive Cooling potential of the building. As a result, a Courtyard would perform as an efficient passive Cooling system when its proportions are approximately 1: 2. 5.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Saligheh, E., & Saadatjou, P.. (2020). Impact of Central Courtyard Proportions on Passive Cooling Potential in Hot and Humid Regions (Case Study: Single-story Buildings in Bandar Abbas). NAQSHEJAHAN, 10(2 ), 137-152. SID. https://sid.ir/paper/378741/en

    Vancouver: Copy

    Saligheh E., Saadatjou P.. Impact of Central Courtyard Proportions on Passive Cooling Potential in Hot and Humid Regions (Case Study: Single-story Buildings in Bandar Abbas). NAQSHEJAHAN[Internet]. 2020;10(2 ):137-152. Available from: https://sid.ir/paper/378741/en

    IEEE: Copy

    E. Saligheh, and P. Saadatjou, “Impact of Central Courtyard Proportions on Passive Cooling Potential in Hot and Humid Regions (Case Study: Single-story Buildings in Bandar Abbas),” NAQSHEJAHAN, vol. 10, no. 2 , pp. 137–152, 2020, [Online]. Available: https://sid.ir/paper/378741/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops

  • No record.





  • Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button