مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

535
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Experimental Investigation of Energy Dissipation over Stepped-Labyrinth Weirs

Pages

  59-74

Abstract

 Flow water passing through spillways of dams has a high level of kinetic energy, which can lead to extensive damage to downstream facilities and bring about severe erosion of river beds. Energy Dissipation would usually be accomplished by creating structures such as still basins at downstream of weirs, flip buckets, or steps in weirs. Stepped spillways are one of the common structures for Energy Dissipation, as well as reduction of the dimensions of still basins. The effects of labyrinths on total Energy Dissipation at downstream of the stepped spillways with slopes of 1: 1, 1: 2 and 1: 3 was investigated; the height of labyrinths was 0. 5 and 0. 75 of the height of steps (h), working interspaces were equal to two times of the height of steps, and three Roughness heights on the step face were 0. 002, 0. 004 and 0. 006 m. The results showed that in first case, 1: 1 slope of the stepped spillway, a labyrinth with height of 0. 5h, working interspaces of 2h and equal length of the steps caused an increase of 12. 7 percent in dissipation of relative energy. The comparison of results showed that for slope of Stepped Weir of 1: 2, installation of a labyrinth with a height of 0. 75h, interspaces of 2h and equal length to the height of the steps, the relative Energy Dissipation increased by 8. 4 percent. When Stepped Weirs with slopes equal to1: 3 were used, results indicated that installation sill with a length h, a height of 0. 5h instead of labyrinths on steps, caused an increase of 4. 7 percent in relative Energy Dissipation. Result showed that increase surface Roughness of studied weirs reduced the relative Energy Dissipation by 3. 6 percent.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Keshavarz Eskandari, M., & ESMAEILI VARAKI, M.. (2019). Experimental Investigation of Energy Dissipation over Stepped-Labyrinth Weirs. IRRIGATION AND DRAINAGE STRUCTURES ENGINEERING RESEARCH , 20(74 ), 59-74. SID. https://sid.ir/paper/397642/en

    Vancouver: Copy

    Keshavarz Eskandari M., ESMAEILI VARAKI M.. Experimental Investigation of Energy Dissipation over Stepped-Labyrinth Weirs. IRRIGATION AND DRAINAGE STRUCTURES ENGINEERING RESEARCH [Internet]. 2019;20(74 ):59-74. Available from: https://sid.ir/paper/397642/en

    IEEE: Copy

    M. Keshavarz Eskandari, and M. ESMAEILI VARAKI, “Experimental Investigation of Energy Dissipation over Stepped-Labyrinth Weirs,” IRRIGATION AND DRAINAGE STRUCTURES ENGINEERING RESEARCH , vol. 20, no. 74 , pp. 59–74, 2019, [Online]. Available: https://sid.ir/paper/397642/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button