مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

290
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Evaluating Seismic Response of Plan Irregular Buildings Using combination of Lead Rubber Bearing Isolator and Friction Pendulum System

Pages

  141-163

Abstract

 Recently, base isolation techniques are applied as a resisting system to protect the structures from seismic and dynamic loadings. Due to their importance, in this paper, an Optimum arrangement of Lead rubber bearing (LRB) and Friction pendulum system (FPS) is investigated in Irregular buildings and its performance is compared with a regular case. For this purpose, 3 types of irregularities have been adopted. Accordingly, 3, 7 and 10 story buildings have been performed and 12 possible combination have been applied for the isolators in each model. Afterwards, the numerical models have been analyzed using nonlinear time-history analysis and direct integration method and applying 7 earthquake records along the longitudinal and transverse directions of the building. The obtained results of the numerical study show that the application of FPS and LRB isolators in outer and inner columns respectively, led to a better performance compared to the other arrangements by reduction of the inter-story drifts as well as base shear and enhancement of the energy dissipation which is due to the characteristics of FPS isolators in balancing the applied forces with the building’ s mass and prevention of torsion occurrence in irregular structures. Unlike the Irregular buildings, application of FPS and LRB isolators in inner and outer columns, result in a better performance by reducing the story drifts in regular structures.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SHIRAVAND, M.R., & Ketabdari, H.. (2021). Evaluating Seismic Response of Plan Irregular Buildings Using combination of Lead Rubber Bearing Isolator and Friction Pendulum System. JOURNAL OF STRUCTURAL AND CONSTRUCTION ENGINEERING, 8(4 ), 141-163. SID. https://sid.ir/paper/403948/en

    Vancouver: Copy

    SHIRAVAND M.R., Ketabdari H.. Evaluating Seismic Response of Plan Irregular Buildings Using combination of Lead Rubber Bearing Isolator and Friction Pendulum System. JOURNAL OF STRUCTURAL AND CONSTRUCTION ENGINEERING[Internet]. 2021;8(4 ):141-163. Available from: https://sid.ir/paper/403948/en

    IEEE: Copy

    M.R. SHIRAVAND, and H. Ketabdari, “Evaluating Seismic Response of Plan Irregular Buildings Using combination of Lead Rubber Bearing Isolator and Friction Pendulum System,” JOURNAL OF STRUCTURAL AND CONSTRUCTION ENGINEERING, vol. 8, no. 4 , pp. 141–163, 2021, [Online]. Available: https://sid.ir/paper/403948/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button