مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

317
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Design and Implementation of High Impedance Fault Relay Based on Harmonic Analysis Algorithm for Ahvaz 33 kV Distribution Network

Pages

  153-166

Keywords

high impedance fault (HIF)Q1

Abstract

 Over current relays that are used commonly in distribution system can't detect high impedance fault. Therefore for that purpose it is necessary to design special algorithms. In this paper, a method based on Harmonic analysis is presented. In this technique, the proposed relay, after fault occurs, extracts the required harmonic and according designed algorithm, occurrence of fault is reported. Software of this relay for different scenarios of high impedance faults was tested; also its hardware of relay in laboratory tests could correctly identify events.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MONADI, M., SEIFOSSADAT, S.GH., KIANINEZHAD, R., & Baharipour, m.. (2021). Design and Implementation of High Impedance Fault Relay Based on Harmonic Analysis Algorithm for Ahvaz 33 kV Distribution Network. NASHRIYYAH -I MUHANDISI -I BARQ VA MUHANDISI -I KAMPYUTAR -I IRAN, A- MUHANDISI -I BARQ, 19(3 ), 153-166. SID. https://sid.ir/paper/412926/en

    Vancouver: Copy

    MONADI M., SEIFOSSADAT S.GH., KIANINEZHAD R., Baharipour m.. Design and Implementation of High Impedance Fault Relay Based on Harmonic Analysis Algorithm for Ahvaz 33 kV Distribution Network. NASHRIYYAH -I MUHANDISI -I BARQ VA MUHANDISI -I KAMPYUTAR -I IRAN, A- MUHANDISI -I BARQ[Internet]. 2021;19(3 ):153-166. Available from: https://sid.ir/paper/412926/en

    IEEE: Copy

    M. MONADI, S.GH. SEIFOSSADAT, R. KIANINEZHAD, and m. Baharipour, “Design and Implementation of High Impedance Fault Relay Based on Harmonic Analysis Algorithm for Ahvaz 33 kV Distribution Network,” NASHRIYYAH -I MUHANDISI -I BARQ VA MUHANDISI -I KAMPYUTAR -I IRAN, A- MUHANDISI -I BARQ, vol. 19, no. 3 , pp. 153–166, 2021, [Online]. Available: https://sid.ir/paper/412926/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top