مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

473
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

221
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

FOCUS ION BEAM PREPARATION OF TRANSMISSION ELECTRON MICROSCOPE SAMPLE IN POLYMER CLAY NANOCOMPOSITE

Pages

  539-545

Abstract

 This paper deals with preparation of PE clay nanocomposite specimen for TRANSMISSION ELECTRON MICROSCOPY (TEM) and studying the difference between dispersion of clay in low density polyethylene using poly(hydrogen methyl siloxane) (PHMS) as coupling agent and untreated one. Argon ion milling is the conventional means by which film sections are thinned to electron transparency for TEM analysis, but this technique exhibits significant problems. In particular, selective thinning and imaging of sub-micrometer inclusions during sample milling are highly problematic. We have achieved successful results using the focused ion beam (FIB) lift-out technique, which utilizes a 30 kV Ga+ ion beam to extract electron transparent specimens with nanometer scale precision. Using this procedure, we have prepared a number of thin film materials representing a range of structures and compositions for TEM analysis.
We believe that FIB milling will create major new opportunities in the field of thin film nanocomposite materials microanalysis. FIB Cutting technique has been successfully applied to prepare TEM specimens of nano-sized clay in low density polyethylene film. In order to see the effect of dispersion and adhesion of clay to matrix using coupling agent a series of PE clay nanocomposite containing clay encapsulated by PHMS, untreated clay were prepared by melt blending. The effects of coating on clays and dispersion of clay in low density polyethylene were studied by TEM.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HASHEMI, SEYED ALI, SAHRAIAN, R., LAFLEUR, P.G., & STOEFFLER, K.. (2006). FOCUS ION BEAM PREPARATION OF TRANSMISSION ELECTRON MICROSCOPE SAMPLE IN POLYMER CLAY NANOCOMPOSITE. IRANIAN POLYMER JOURNAL (ENGLISH), 15(7 (73)), 539-545. SID. https://sid.ir/paper/538091/en

    Vancouver: Copy

    HASHEMI SEYED ALI, SAHRAIAN R., LAFLEUR P.G., STOEFFLER K.. FOCUS ION BEAM PREPARATION OF TRANSMISSION ELECTRON MICROSCOPE SAMPLE IN POLYMER CLAY NANOCOMPOSITE. IRANIAN POLYMER JOURNAL (ENGLISH)[Internet]. 2006;15(7 (73)):539-545. Available from: https://sid.ir/paper/538091/en

    IEEE: Copy

    SEYED ALI HASHEMI, R. SAHRAIAN, P.G. LAFLEUR, and K. STOEFFLER, “FOCUS ION BEAM PREPARATION OF TRANSMISSION ELECTRON MICROSCOPE SAMPLE IN POLYMER CLAY NANOCOMPOSITE,” IRANIAN POLYMER JOURNAL (ENGLISH), vol. 15, no. 7 (73), pp. 539–545, 2006, [Online]. Available: https://sid.ir/paper/538091/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button