مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

867
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

OPTIMUM DESIGN OF A KNEE ORTHOSIS POWERED BY SERIES ELASTIC ACTUATORS

Pages

  305-316

Abstract

 The statistical studies indicate that diseases, accidents and wares are the principal causes to increase the number of amputees in the world. These studies also show that the most of mutilation disabilities are related to musculoskeletal. Obesity, sedentary, lack of proper exercise as well as the risk of some diseases, cause weaken in knee muscles and other difficulties of this hand. As a consequence, the knee muscles can't apply a mighty torque to accomplish knee motion. The objective of this study is to propose a proper solution to improve the life quality of those who suffer from weak knees.in this study, by investigating the biomechanical behavior of a healthy foot in a normal GAIT, the indispensable power which can enforce a 50% weak Knee to achieve the same GAIT can be calculated. To naturalize the mentioned knee, a new control-active orthosis is designed. The proposed design is specified by an electromechanical actuator and an elastic component articulated in a light weight four-bar mechanism. Its mechanical behavior is tested in a simulated walking GAIT and the optimum value of elastic coefficient is estimated as 7KN/m. In this case, the maximum torque applicable to knee joint has increased by 34 per cent.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SAMERI NEDAFI, R., MOAZEMI GOUDARZI, A., & FATHI, A.R.. (2015). OPTIMUM DESIGN OF A KNEE ORTHOSIS POWERED BY SERIES ELASTIC ACTUATORS. IRANIAN JOURNAL OF BIOMEDICAL ENGINEERING, 9(3), 305-316. SID. https://sid.ir/paper/81671/en

    Vancouver: Copy

    SAMERI NEDAFI R., MOAZEMI GOUDARZI A., FATHI A.R.. OPTIMUM DESIGN OF A KNEE ORTHOSIS POWERED BY SERIES ELASTIC ACTUATORS. IRANIAN JOURNAL OF BIOMEDICAL ENGINEERING[Internet]. 2015;9(3):305-316. Available from: https://sid.ir/paper/81671/en

    IEEE: Copy

    R. SAMERI NEDAFI, A. MOAZEMI GOUDARZI, and A.R. FATHI, “OPTIMUM DESIGN OF A KNEE ORTHOSIS POWERED BY SERIES ELASTIC ACTUATORS,” IRANIAN JOURNAL OF BIOMEDICAL ENGINEERING, vol. 9, no. 3, pp. 305–316, 2015, [Online]. Available: https://sid.ir/paper/81671/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button