مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

202
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Sensitivity Analysis of Friction Tuned Mass Damper and its Performance Compared to Tuned Mass Damper at Different Seismic Hazard Levels

Pages

  123-136

Abstract

 One of the most up-to-date seismic control devices are Tuned Mass Damper/fa?page=1&sort=1&ftyp=all&fgrp=all&fyrs=all" target="_blank">Friction Tuned Mass Damper (FTMD). This type of damper is a combination of a Tuned Mass Damper (TMD) and a nonlinear frictional damper. In this paper, the governing equations for a single-degree-of-freedom (SDOF) structure equipped with a FTMD and effective parameters on these systems performance are expressed first. Then, SDOF structures with linear behavior equipped with a FTMD are modeled and validated in OpenSEES software. Finally, the sensitivity analysis of these models to their effective parameters is performed. The structures mass is assumed to be 10 tons, their period is 0. 5 second and their damping ratio is assumed to be 2%. Nonlinear time history analyses are done for these structures using 40 strong ground motions from the SAC project. These ground motions consist of 20 records (La01-La20) at design basis earthquake (DBE) level and 20 records (La21-La40) at maximum considered earthquake (MCE) level for the Los Angeles area. Effective parameters on the performance of FTMD assumed in this study are the friction coefficient of the damper, the mass ratio of the damper to the structure and the frequency ratio of the damper to the structure. Average of the structures' maximum displacement is determined for two ground motion records sets and effects of the mentioned parameters on the structural performance are discussed. Results show that the responses are more sensitive to frequency ratio rather than friction coefficient and mass ratio. The best value for the friction coefficient varies between 0. 1 and 0. 3 at DBE level, and varies between 0. 2 and 0. 4 for MCE level. Based on the results obtained for SDOF structures, application of FTMD on multi-degree-of-freedom (MDOF) is discussed in the next step. This is done for short period structures because this type of damper is more effective on these structures. Three MDOF structures with linear behavior and period of 0. 3, 0. 5 and 1 second are selected and the seismic performance of these structures equipped with FTMD is investigated and compared with the same structures equipped with Tuned Mass Damper (TMD). The mass of stories is uniformly distributed among structure and the mass of each story is 10 ton. In addition, the damping ratio for the main structure in all models is assumed to be 2% and the stiffness of the stories is decreased linearly with the triangular pattern. Same ground motion records are used for the nonlinear time history analysis of MDOF structures and the results for the mean maximum relative displacement of the stories under DBE and MCE levels are compared for structures with FTMD and TMD. Results show that the structures equipped with FTMD have better performance than the structures equipped with TMD, but with increasing structures period, performance of two systems approach each other. In addition, 3 and 5 story structures equipped with FTMD have better performance at DBE level while a 10-story structure equipped with this damper has better performance at DBE level

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    TAJMIR RIAHI, HOSSEIN, & Shams Falavarjani, Raheleh. (2020). Sensitivity Analysis of Friction Tuned Mass Damper and its Performance Compared to Tuned Mass Damper at Different Seismic Hazard Levels. BULLETIN OF EARTHQUAKE SCIENCE AND ENGINEERING, 7(1 ), 123-136. SID. https://sid.ir/paper/954367/en

    Vancouver: Copy

    TAJMIR RIAHI HOSSEIN, Shams Falavarjani Raheleh. Sensitivity Analysis of Friction Tuned Mass Damper and its Performance Compared to Tuned Mass Damper at Different Seismic Hazard Levels. BULLETIN OF EARTHQUAKE SCIENCE AND ENGINEERING[Internet]. 2020;7(1 ):123-136. Available from: https://sid.ir/paper/954367/en

    IEEE: Copy

    HOSSEIN TAJMIR RIAHI, and Raheleh Shams Falavarjani, “Sensitivity Analysis of Friction Tuned Mass Damper and its Performance Compared to Tuned Mass Damper at Different Seismic Hazard Levels,” BULLETIN OF EARTHQUAKE SCIENCE AND ENGINEERING, vol. 7, no. 1 , pp. 123–136, 2020, [Online]. Available: https://sid.ir/paper/954367/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button