مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

123
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Investigation on Primary Stability of Dental Implants during Compressive Cyclic Loading-Unloading using μ CT Imaging, and Digital Volume Correlation (DVC) Method

Pages

  151-159

Abstract

Primary Stability is the initial mechanical engagement of the implant with its neighboring bone, which can be assessed through in-vitro assessment of stiffness and the ultimate load of the bone-implant complex. Implantation and the following loading on an implant after implantation, could cause mechanical damage in the peripheral bone, and subsequently, reduce the Primary Stability of the implant. This study aimed at finding the effects of damage induced in the bone through exerting compressive loadingunloading cycles on the Primary Stability of the bone-implant system. For this purpose, firstly, a cylindrical bone sample was extracted from the proximal part of a bovine tibia. After implantation and bone-implant preparation, a quasi-static compressive step-wise loading-unloading cycles, with a displacement rate of 0. 0024 mm/s and displacementcontrolled were applied to the bone-implant structure with the amplitudes of 0. 04 mm to 1. 28 mm. In each step, after unloading, μ CT images was captured from the boneimplant sample. Finally, the stiffness of the structure in each step and ultimate load were obtained from the mechanical test. The distribution of plastic stain in the bone due to loading-unloading of the construct was calculated using Digital Volume Correlation, through correlating the μ CT images before and after each loading step. Results of this work showed that increasing the step-wise displacement amplitude from 0 to 0. 96 mm caused a stiffness reduction of 40%, compared to the initial stiffness. Also, the Digital Volume Correlation results showed that maximum Plastic Strain occurred in the neighboring bone in the crestal part of dental implant, and also increasing loading amplitude from 0. 64 to 0. 96 mm led to 1. 5% increase in the maximum Plastic Strain. It is hoped that results of this kind of investigation can be helpful in optimizing the dental implants design, with the approach of increasing their stability.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Akhlaghi, Pedram, Khorshidparast, Setareh, Rouhi, Gholamreza, & BARIKANI, HAMIDREZA. (2021). Investigation on Primary Stability of Dental Implants during Compressive Cyclic Loading-Unloading using μ CT Imaging, and Digital Volume Correlation (DVC) Method. IRANIAN JOURNAL OF BIOMEDICAL ENGINEERING, 15(2 ), 151-159. SID. https://sid.ir/paper/985150/en

    Vancouver: Copy

    Akhlaghi Pedram, Khorshidparast Setareh, Rouhi Gholamreza, BARIKANI HAMIDREZA. Investigation on Primary Stability of Dental Implants during Compressive Cyclic Loading-Unloading using μ CT Imaging, and Digital Volume Correlation (DVC) Method. IRANIAN JOURNAL OF BIOMEDICAL ENGINEERING[Internet]. 2021;15(2 ):151-159. Available from: https://sid.ir/paper/985150/en

    IEEE: Copy

    Pedram Akhlaghi, Setareh Khorshidparast, Gholamreza Rouhi, and HAMIDREZA BARIKANI, “Investigation on Primary Stability of Dental Implants during Compressive Cyclic Loading-Unloading using μ CT Imaging, and Digital Volume Correlation (DVC) Method,” IRANIAN JOURNAL OF BIOMEDICAL ENGINEERING, vol. 15, no. 2 , pp. 151–159, 2021, [Online]. Available: https://sid.ir/paper/985150/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button