مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

409
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Experimental Investigation of One-Loop Galloping in Power Transmission Conductors and the Effect of Local Covering to it’ s Alleviate

Pages

  1171-1185

Abstract

Galloping is a large-amplitude, low frequency, wind-induced oscillation of overhead power transmission lines with one or multi loops of standing waves per span which occurs due to wind flow. Based on the field data, numerous Galloping oscillations occurs in the form of one loop oscillation which whereby high dynamic loads are imported to the support structures. In this research, the results of Wind Tunnel tests have been performed on a two-span distorted scale model with an ice-accreted cross-section under uniform and non-uniform Aerodynamic Loadings. Dead-end and suspension Insulators have been applied to the support points. Then, based on identifying the most critical state of the lines oscillation, a solution has been proposed based on increasing their bending strength through the application of hardening Local Covering. The results showed that the most critical state of the cables oscillation in the Galloping is related to the one-loop oscillation, which occurs as a result of interactions between the cables of adjacent spans under uneven Aerodynamic Loading and the use of suspended Insulators, and the dynamic forces applied to the supports are about 20% more than the case when the cables oscillate due to the dead-end connections attached to the support structure. Also, applying the Local Covering with a length of 20% of cable span leads to a 27% reduction in dynamic support reaction of one-loop Galloping.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SABBAGH YAZDI, S.R., & JAMSHIDI, M.. (2020). Experimental Investigation of One-Loop Galloping in Power Transmission Conductors and the Effect of Local Covering to it’ s Alleviate. MODARES MECHANICAL ENGINEERING, 20(5 ), 1171-1185. SID. https://sid.ir/paper/178535/en

    Vancouver: Copy

    SABBAGH YAZDI S.R., JAMSHIDI M.. Experimental Investigation of One-Loop Galloping in Power Transmission Conductors and the Effect of Local Covering to it’ s Alleviate. MODARES MECHANICAL ENGINEERING[Internet]. 2020;20(5 ):1171-1185. Available from: https://sid.ir/paper/178535/en

    IEEE: Copy

    S.R. SABBAGH YAZDI, and M. JAMSHIDI, “Experimental Investigation of One-Loop Galloping in Power Transmission Conductors and the Effect of Local Covering to it’ s Alleviate,” MODARES MECHANICAL ENGINEERING, vol. 20, no. 5 , pp. 1171–1185, 2020, [Online]. Available: https://sid.ir/paper/178535/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button