مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

752
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

135
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

PREPARATION AND APPLICATION OF AL3+- SENSOR BASED ON (2Z)-METHYL 2- ((Z) (P-TOLYLIMINO) -3-ETHYL -4-OXOTHIAZOLIDIN -5- YLIDENE ACETATE IN PVC MATRIX

Pages

  295-304

Keywords

AL3+-SELECTIVE ELECTRODEQ2

Abstract

 Al3+-Potentiometric sensor, based on (2Z) -methyl 2- ((z) (p-tolylimino) -3-ethyl -4-oxothiazolidin -5- ylidene) Acetate (MTEOY) as a neutral ionophore, was successfully developed for the detection of Al3+in aqueous solutions. The electrode responds to Al3+ion with a sensitivity of 19.8±0.1 mV/ decade over the range 1.0 × 10-8 -1.0 × 10-1 mol L-1 and in a pH range of 3.0-9.0. The electrode shows a detection limit of 3.5 × 10-9 mol L-1. The influence of membrane composition, the pH of the test solution, and the interfering ions on the electrode performance was investigated. The proposed electrode shows good discrimination of Al3+ion from several cations. The effect of temperature on the electrode response shows that the temperature higher than 50oC deteriorates the electrode performance. The electrode was found to work well under laboratory conditions. This sensor not only was used in determination of Al3+in real samples but also was used to determination of Al3+ concentration in the presence of certain interfering ions.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MOFIDI, J., ISLAMNEZHAD, A., & POUR HOJAT, F.. (2012). PREPARATION AND APPLICATION OF AL3+- SENSOR BASED ON (2Z)-METHYL 2- ((Z) (P-TOLYLIMINO) -3-ETHYL -4-OXOTHIAZOLIDIN -5- YLIDENE ACETATE IN PVC MATRIX. JOURNAL OF PHYSICAL AND THEORETICAL CHEMISTRY, 8(4), 295-304. SID. https://sid.ir/paper/207735/en

    Vancouver: Copy

    MOFIDI J., ISLAMNEZHAD A., POUR HOJAT F.. PREPARATION AND APPLICATION OF AL3+- SENSOR BASED ON (2Z)-METHYL 2- ((Z) (P-TOLYLIMINO) -3-ETHYL -4-OXOTHIAZOLIDIN -5- YLIDENE ACETATE IN PVC MATRIX. JOURNAL OF PHYSICAL AND THEORETICAL CHEMISTRY[Internet]. 2012;8(4):295-304. Available from: https://sid.ir/paper/207735/en

    IEEE: Copy

    J. MOFIDI, A. ISLAMNEZHAD, and F. POUR HOJAT, “PREPARATION AND APPLICATION OF AL3+- SENSOR BASED ON (2Z)-METHYL 2- ((Z) (P-TOLYLIMINO) -3-ETHYL -4-OXOTHIAZOLIDIN -5- YLIDENE ACETATE IN PVC MATRIX,” JOURNAL OF PHYSICAL AND THEORETICAL CHEMISTRY, vol. 8, no. 4, pp. 295–304, 2012, [Online]. Available: https://sid.ir/paper/207735/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button