مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,158
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DUAL LOOP CONTROL OF 400 HZ INVERTER FOR GROUND POWER UNITS

Pages

  36-46

Abstract

 In this paper DUAL-LOOP CONTROL method is proposed for control of 400 HZ INVERTER. Resonant controllers are used in the outer loop to regulate the amplitude of fundamental harmonic and to remove the unwanted harmonics. To avoid phase delay and bandwidth degradation, proportional controller is used as the inner control loop. In this paper, HYBRID DIGITAL DESIGN in discrete- and continuous-time domain is introduced to design the inner and outer control loops. To decouple the control system from the load current disturbances and to improve the dynamic performance, a feed-forward path is added to the DUAL-LOOP CONTROL structure. To reduce the noise of feed-forward path, a soft-derivative term is introduced which is optimized for 400 Hz frequency. To verify the system performance, several simulations have been carried out which shows satisfactory results under dynamic and steady state conditions. Finally, the experimental results of a 20 kVA hardware prototype is presented to confirm the validity of theoretical and simulation results.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    NOURI, M., & IMAN EINI, H.. (2016). DUAL LOOP CONTROL OF 400 HZ INVERTER FOR GROUND POWER UNITS. NASHRIYYAH -I MUHANDISI -I BARQ VA MUHANDISI -I KAMPYUTAR -I IRAN, A- MUHANDISI -I BARQ, 14(1), 36-46. SID. https://sid.ir/paper/228154/en

    Vancouver: Copy

    NOURI M., IMAN EINI H.. DUAL LOOP CONTROL OF 400 HZ INVERTER FOR GROUND POWER UNITS. NASHRIYYAH -I MUHANDISI -I BARQ VA MUHANDISI -I KAMPYUTAR -I IRAN, A- MUHANDISI -I BARQ[Internet]. 2016;14(1):36-46. Available from: https://sid.ir/paper/228154/en

    IEEE: Copy

    M. NOURI, and H. IMAN EINI, “DUAL LOOP CONTROL OF 400 HZ INVERTER FOR GROUND POWER UNITS,” NASHRIYYAH -I MUHANDISI -I BARQ VA MUHANDISI -I KAMPYUTAR -I IRAN, A- MUHANDISI -I BARQ, vol. 14, no. 1, pp. 36–46, 2016, [Online]. Available: https://sid.ir/paper/228154/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button