مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

830
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Study of Flotation Kinetic of Kermanshah State Gilsonite

Pages

  197-206

Abstract

 In order to determination of flotation kinetic and particle size effect on it, flotation tests were conducted on a Gilsonite sample of Kermanshah state. Therefore, rougher and cleaner flotation tests through the oil collector-MIBC (Methyl Iso Butyl Carbonyl) frother, Gasoline collector – Pine oil frother and one test without any collector and frother, was done. Concentrates obtained from the tests weighted and ash analysis was taken from them, also all of the concentrates were grading, in different intervals. Then, for each test, drawn recovery – time graph and were fitted by using different first-order kinetics model. According to the graph observed that the results of all tests have high compliance with first order classic model. Kinetics constant calculated with the classic model are as follows, the rougher tests, oil collector – MIBC frother 0. 0303, Gasoline collector – pine oil frother 0. 0301 and test without any collector and frother is 0. 0161. Also, the amount of k respectively the above collector and frother 0. 0168, 0. 048, 0. 013 was calculated in cleaner tests, then the retention time and flotation cell volume according to k calculated. In this research, studied the relationship between flotation rate constant, maximum recovery and particle size too. The results show that maximum flotation recovery and flotation rate in rougher tests belongs to flotation test without any collector and frother with a particle size in rang-850, +500 µ m. as well as, in the cleaner test, maximum flotation recovery and flotation rate related to the test with Gasoline collector and pine oil frother with-850, +500 µ m particle size.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KAZEMI, FATEMEH, BAHRAMI, ATAALLAH, & ABDOLLAHI SHARIF, JAFAR. (2018). Study of Flotation Kinetic of Kermanshah State Gilsonite. NASHRIEH SHIMI VA MOHANDESI SHIMI IRAN (PERSIAN), 37(1 ), 197-206. SID. https://sid.ir/paper/26120/en

    Vancouver: Copy

    KAZEMI FATEMEH, BAHRAMI ATAALLAH, ABDOLLAHI SHARIF JAFAR. Study of Flotation Kinetic of Kermanshah State Gilsonite. NASHRIEH SHIMI VA MOHANDESI SHIMI IRAN (PERSIAN)[Internet]. 2018;37(1 ):197-206. Available from: https://sid.ir/paper/26120/en

    IEEE: Copy

    FATEMEH KAZEMI, ATAALLAH BAHRAMI, and JAFAR ABDOLLAHI SHARIF, “Study of Flotation Kinetic of Kermanshah State Gilsonite,” NASHRIEH SHIMI VA MOHANDESI SHIMI IRAN (PERSIAN), vol. 37, no. 1 , pp. 197–206, 2018, [Online]. Available: https://sid.ir/paper/26120/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button