Title

CHLORIDE-INDUCED CORROSION OF RC STRUCTURES

Pages

  531-547

Abstract

 This paper describes the SERVICE LIFE of the reinforced CONCRETE (RC) structures in CHLORIDE laden environments. Presence of CHLORIDE ions is the most important causes of reinforcing steel CORROSION and the subsequent failure of the whole structure. In this paper, the rate of CHLORIDE transport in the CONCRETE is defined using Fick’s second law of diffusion. Various stages of CORROSION process are defined base on the available models. A stochastic model is introduced for RC structures CORROSION initiation period and cover CRACKING time period. It is concluded that a “Lognormal” distribution might best describe the initiation period of CORROSION. Moreover, it is found that the “Lognormal” and “Normal” distributions could define the CRACKING time of RC structures elements appropriately.

Cites

References

  • No record.
  • Cite

    APA: Copy

    SOBHANI, J., & RAMEZANIANPOUR, A.A.. (2007). CHLORIDE-INDUCED CORROSION OF RC STRUCTURES. ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING), 8(5), 531-547. SID. https://sid.ir/paper/298752/en

    Vancouver: Copy

    SOBHANI J., RAMEZANIANPOUR A.A.. CHLORIDE-INDUCED CORROSION OF RC STRUCTURES. ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING)[Internet]. 2007;8(5):531-547. Available from: https://sid.ir/paper/298752/en

    IEEE: Copy

    J. SOBHANI, and A.A. RAMEZANIANPOUR, “CHLORIDE-INDUCED CORROSION OF RC STRUCTURES,” ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING), vol. 8, no. 5, pp. 531–547, 2007, [Online]. Available: https://sid.ir/paper/298752/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button