Information Journal Paper

Title

SEPARATION GAP, A CRITICAL FACTOR IN EARTHQUAKE INDUCED POUNDING BETWEEN ADJACENT BUILDINGS

Pages

  881-898

Keywords

FIXED-BASED (FB) BUILDINGS 
STRUCTURE-SOIL-STRUCTURE INTERACTION (SSSI) 

Abstract

 In this paper it is attempted to study SEISMIC RESPONSEs of adjacent buildings subjected to earthquake induced pounding and to clarify pounding effects for various SEPARATION GAPs. An analytical model of adjacent buildings resting on a half-space is provided whilst the buildings are connected by visco-elastic contact force model. Results show that with same SEPARATION GAP, adjacent buildings with structure-soil-structure interaction (SSSI) are more likely to pound together than buildings with fixed-based (FB) condition. Also, building condition gets worse due to pounding because the SEISMIC RESPONSEs of buildings are unfavourably increased and the condition becomes more critical if the SEPARATION GAP becomes narrower.

Cites

References

Cite

APA: Copy

NASERKHAKI, S., EL RICH, M., ABDUL AZIZ, F.N.A., & POURMOHAMMAD, H.. (2013). SEPARATION GAP, A CRITICAL FACTOR IN EARTHQUAKE INDUCED POUNDING BETWEEN ADJACENT BUILDINGS. ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING), 14(6), 881-898. SID. https://sid.ir/paper/299089/en

Vancouver: Copy

NASERKHAKI S., EL RICH M., ABDUL AZIZ F.N.A., POURMOHAMMAD H.. SEPARATION GAP, A CRITICAL FACTOR IN EARTHQUAKE INDUCED POUNDING BETWEEN ADJACENT BUILDINGS. ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING)[Internet]. 2013;14(6):881-898. Available from: https://sid.ir/paper/299089/en

IEEE: Copy

S. NASERKHAKI, M. EL RICH, F.N.A. ABDUL AZIZ, and H. POURMOHAMMAD, “SEPARATION GAP, A CRITICAL FACTOR IN EARTHQUAKE INDUCED POUNDING BETWEEN ADJACENT BUILDINGS,” ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING), vol. 14, no. 6, pp. 881–898, 2013, [Online]. Available: https://sid.ir/paper/299089/en

Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button