مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

404
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

205
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

PREPARATION OF A CHELATING RESIN AND ITS APPLICATION AS A PRECONCENTRATION SYSTEM FOR DETERMINATION OF CADMIUM IN RIVER WATER BY FLOW INJECTION ANALYSIS

Pages

  531-536

Abstract

 A CHELATING RESIN of polystyrene divinylbenzene resin functionalized by 1-(2-pyridylazo) 2- naphtol (PSDVB-PAN) has been synthesized and its sorption properties have been investigated for preconcentration and determination of CADMIUM at μg/L level by flame atomic absorption spectrometry. The procedure is based on the sorption of Cd(II) ions on a minicolumn of synthesized CHELATING RESIN. The retained CADMIUM ions can be quickly eluted from sorbent material, with the eluent stream consisting of nitric acid solution, directly to the nebulizer burner system of the flame atomic absorption spectrometer. The sorption capacity of PSDVB-PAN was found to be 7.5 mg/g at optimum pH and the CHELATING RESIN showed rapid kinetic sorption. The sorption equilibrium of Cd(II) on synthesized CHELATING RESIN was achieved just in 15 minutes. Parameters such as the pH effect on the CADMIUM sorption, sample volume, the sorption capacity of resin, the CADMIUM desorption from the resin and the analytical characteristics of the procedure were studied for the quantitative recoveries of the analyte ions. The developed system allowed a throughput rate of 15 samples h-1 with a detection limit of 1.5mg/L. Relative standard deviation for 5 replicated injections of 50mg/ L was 1.8%. This procedure was applied for CADMIUM determination in river water samples collected from Citarum River, West Java, Indonesia.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    AMRAN, M.B., PANGGABEAN, A.S., SULAEMAN, A., & RUSNADI, M.. (2011). PREPARATION OF A CHELATING RESIN AND ITS APPLICATION AS A PRECONCENTRATION SYSTEM FOR DETERMINATION OF CADMIUM IN RIVER WATER BY FLOW INJECTION ANALYSIS. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH (IJER), 5(2), 531-536. SID. https://sid.ir/paper/300912/en

    Vancouver: Copy

    AMRAN M.B., PANGGABEAN A.S., SULAEMAN A., RUSNADI M.. PREPARATION OF A CHELATING RESIN AND ITS APPLICATION AS A PRECONCENTRATION SYSTEM FOR DETERMINATION OF CADMIUM IN RIVER WATER BY FLOW INJECTION ANALYSIS. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH (IJER)[Internet]. 2011;5(2):531-536. Available from: https://sid.ir/paper/300912/en

    IEEE: Copy

    M.B. AMRAN, A.S. PANGGABEAN, A. SULAEMAN, and M. RUSNADI, “PREPARATION OF A CHELATING RESIN AND ITS APPLICATION AS A PRECONCENTRATION SYSTEM FOR DETERMINATION OF CADMIUM IN RIVER WATER BY FLOW INJECTION ANALYSIS,” INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH (IJER), vol. 5, no. 2, pp. 531–536, 2011, [Online]. Available: https://sid.ir/paper/300912/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button