Information Journal Paper

Title

Determination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11-azabenzo[a]phenothiazin-5-one as a neutral ion carrier

Author(s)

 JALALI SARVESTANI MOHAMMAD REZA | AHMADI ROYA | Issue Writer Certificate 

Pages

  18-35

Keywords

Cobalt (II) 
6 
11 
azabenzo[a]phenothiazin 
5 
one 

Abstract

 Cobalt has great biological effects on human beings and also other living organisms, hence its determination is very important. In this regard, a novel coated graphite electrode was designed for determination of Co2+ ions by exploiting 6-chloro-11-azabenzo[a]phenothiazin-5-one as a neutral ion carrier, for the first time. The foremost function was witnessed from the membrane composition of PVC (29%), Potassium tetrakis (4-chlorophenyl) borate (2%) as an ionic additive, 6-chloro-11-azabenzo[a]phenothiazin-5-one (9%) as ionophore and Dioctylphthalate (60%) as Plasticizer. The linearity domain of the membrane sensor was from 5×10-7 to 1×10-2 Mol L-1 with the Nernstian slope value of 30. 1 mV. Decade-1. The potential response of the designed electrode was also investigated in non-aqueous mediums and it was found out that the electrode is also able to be used in systems that are entailed of 20% of ethanol and acetone organic solvents. The response time and lifespan of the electrode was 5 S and 3 months respectively. The sensor selectivity was also evaluated by match potential method over other cations and it shows an eminent selectivity towards Co2+ over all of the inspected ions. The applicability of the electrode in the potentiometric titration with EDTA was also investigated. In the end, the proposed electrode was utilized for determination of Co2+ in four aqueous specimens as real samples.

Cites

References

  • No record.
  • Cite

    APA: Copy

    JALALI SARVESTANI, MOHAMMAD REZA, & AHMADI, ROYA. (2019). Determination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11-azabenzo[a]phenothiazin-5-one as a neutral ion carrier. JOURNAL OF APPLIED CHEMICAL RESEARCH (JACR), 13(2), 18-35. SID. https://sid.ir/paper/323130/en

    Vancouver: Copy

    JALALI SARVESTANI MOHAMMAD REZA, AHMADI ROYA. Determination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11-azabenzo[a]phenothiazin-5-one as a neutral ion carrier. JOURNAL OF APPLIED CHEMICAL RESEARCH (JACR)[Internet]. 2019;13(2):18-35. Available from: https://sid.ir/paper/323130/en

    IEEE: Copy

    MOHAMMAD REZA JALALI SARVESTANI, and ROYA AHMADI, “Determination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11-azabenzo[a]phenothiazin-5-one as a neutral ion carrier,” JOURNAL OF APPLIED CHEMICAL RESEARCH (JACR), vol. 13, no. 2, pp. 18–35, 2019, [Online]. Available: https://sid.ir/paper/323130/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button