RESPONSE OF BUILDINGS WITH INCLINED FIRST-STORY COLUMNS TO NEAR-FAULT GROUND MOTION

Pages

  19-34

Abstract

 In this paper a simple model of a three story building with INCLINED FIRST-STORY COLUMNs has presented. The stories are supposed to be rigid and are connected to axially rigid mass less columns by elasto-plastic rotational springs and linear rotational dampers. The considered model is subjected to horizontal component of fault normal pulse with different magnitudes and the governed nonlinear differential equations of motion have been solved by the forth order Runge-Kutta method. Results indicate that the inclination of the first-story columns stiffens the system. However, the change of the frequency of the first mode is small. The deformation of the first story with inclined columns is such that it forces the building in a pendulum-like motion. So it would be possible to reduce the relative building response. Results indicate that an optimum value of inclination angle of the first-story columns is. Under this condition the first-story drift decreases while upper-story drift increases, respect to the common building with. For larger inclination angles the gravity effect leads to increase the first-story drift as well. This solution would be useful in earthquake resistant design of buildings which have architectural limitations at the first story.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ROUZMEHR, F., & SALEH JALALI, R.. (2014). RESPONSE OF BUILDINGS WITH INCLINED FIRST-STORY COLUMNS TO NEAR-FAULT GROUND MOTION. JOURNAL OF REHABILITATION IN CIVIL ENGINEERING, 2(1), 19-34. SID. https://sid.ir/paper/339920/en

    Vancouver: Copy

    ROUZMEHR F., SALEH JALALI R.. RESPONSE OF BUILDINGS WITH INCLINED FIRST-STORY COLUMNS TO NEAR-FAULT GROUND MOTION. JOURNAL OF REHABILITATION IN CIVIL ENGINEERING[Internet]. 2014;2(1):19-34. Available from: https://sid.ir/paper/339920/en

    IEEE: Copy

    F. ROUZMEHR, and R. SALEH JALALI, “RESPONSE OF BUILDINGS WITH INCLINED FIRST-STORY COLUMNS TO NEAR-FAULT GROUND MOTION,” JOURNAL OF REHABILITATION IN CIVIL ENGINEERING, vol. 2, no. 1, pp. 19–34, 2014, [Online]. Available: https://sid.ir/paper/339920/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button