مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

331
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

176
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

APPLICATION OF ANN TECHNIQUE FOR INTERCONNECTED POWER SYSTEM LOAD FREQUENCY CONTROL

Pages

  247-254

Abstract

 This paper describes an application of Artificial Neural Networks (ANN) to Load ‎Frequency Control (LFC) of nonlinear POWER SYSTEMS. POWER SYSTEMS, such as other ‎industrial processes, have parametric uncertainties that for controller design had to ‎take the uncertainties into account. For this reason, in the design of LFC controller the ‎idea of ROBUST CONTROL theories are being used. To improve the stability of nonlinear ‎power system, in the various operating point and under different disturbances this ‎controller has been reconstructed with the use of neural network capability based on ‎Radial Basis Function (RBF). The motivation of using the ROBUST CONTROL for training ‎of the RBF neural networks controller is taking the large parametric uncertainties into ‎account in such away that both stability of the overall system and good performance ‎have been achieved for all admissible uncertainties. The simulation results on ‎interconnected power system show that the proposed Nonlinear Neural Controller ‎‎(NNC) not only is robust to increasing of load perturbations and operating point ‎variations, but also the NNC gives good dynamic response compared with ‎conventional III and ROBUST CONTROLlers. It guarantees the stability of the overall system ‎even in the presence of generation rate constraint (GRC‏.(‏

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SHAYEGHI, H., & SHAYANFAR, H.A.. (2003). APPLICATION OF ANN TECHNIQUE FOR INTERCONNECTED POWER SYSTEM LOAD FREQUENCY CONTROL. INTERNATIONAL JOURNAL OF ENGINEERING, 16(3 (TRANSACTIONS B: APPLICATION)), 247-254. SID. https://sid.ir/paper/355296/en

    Vancouver: Copy

    SHAYEGHI H., SHAYANFAR H.A.. APPLICATION OF ANN TECHNIQUE FOR INTERCONNECTED POWER SYSTEM LOAD FREQUENCY CONTROL. INTERNATIONAL JOURNAL OF ENGINEERING[Internet]. 2003;16(3 (TRANSACTIONS B: APPLICATION)):247-254. Available from: https://sid.ir/paper/355296/en

    IEEE: Copy

    H. SHAYEGHI, and H.A. SHAYANFAR, “APPLICATION OF ANN TECHNIQUE FOR INTERCONNECTED POWER SYSTEM LOAD FREQUENCY CONTROL,” INTERNATIONAL JOURNAL OF ENGINEERING, vol. 16, no. 3 (TRANSACTIONS B: APPLICATION), pp. 247–254, 2003, [Online]. Available: https://sid.ir/paper/355296/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button