مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

340
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Voltage Balancing at the Point of Common Coupling of DG Unit Using Decoupled Double Synchronous Reference Frame

Pages

  243-252

Abstract

 Voltage unbalance reduces the power quality and causes problems in the customer equipment and in the grids operation, especially in grids including distributed generation sources. In microgrids, use of distributed generation sources controlled by the inverter, has made it possible to compensate voltage unbalance by distributed generation units. To compensate voltage unbalance, usually two control loops are used to control the positive and negative components in the dq rotary frame. Nevertheless, the control loops of the positive and negative sequences are not completely decoupled from each other and there is an oscillatory coupling between them. In this paper, the use of the decoupled double synchronous reference frame in order to eliminate oscillating couplings and for Voltage unbalance compensation is proposed. The simulation results show that, using the proposed control method, the voltage unbalance at the point of common coupling is effectively reduced. Also, due to the decoupling of the positive sequence from the negative sequence control loop, the performance of the distributed generation unit in the power injection to the grid is not affected by the voltage unbalance control system.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Sharafi, Peyman, & KARIMI, SHAHRAM. (2020). Voltage Balancing at the Point of Common Coupling of DG Unit Using Decoupled Double Synchronous Reference Frame. TABRIZ JOURNAL OF ELECTRICAL ENGINEERING, 50(1 (91) ), 243-252. SID. https://sid.ir/paper/387290/en

    Vancouver: Copy

    Sharafi Peyman, KARIMI SHAHRAM. Voltage Balancing at the Point of Common Coupling of DG Unit Using Decoupled Double Synchronous Reference Frame. TABRIZ JOURNAL OF ELECTRICAL ENGINEERING[Internet]. 2020;50(1 (91) ):243-252. Available from: https://sid.ir/paper/387290/en

    IEEE: Copy

    Peyman Sharafi, and SHAHRAM KARIMI, “Voltage Balancing at the Point of Common Coupling of DG Unit Using Decoupled Double Synchronous Reference Frame,” TABRIZ JOURNAL OF ELECTRICAL ENGINEERING, vol. 50, no. 1 (91) , pp. 243–252, 2020, [Online]. Available: https://sid.ir/paper/387290/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button