مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

481
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Evaluation and Feasibility of Using Heat Exchanger in Kerosene Unit of Persian Gulf Star Oil Refinery for Sour Naphtha Service

Pages

  79-93

Abstract

 One of the strategic goals in the Persian Gulf Star Oil Refinery has been to change the use of the Kerosene Hydrotreater with the Sour Naphtha Service. The purpose of this study is to simulate and evaluate the shell and tube heat exchangers at the outlet of kerosene Hydrotreater unit’ s reactor for Naphtha Service which has been studied as part of a massive, Change Usage project. The simulation results with the HTRI software Version 6. 32, showed that in change of useage with the new service and the without considering fouling, the amount of heat transfer of the mentioned heat exchangers will be sufficient for heat transfer of 22. 2 Mega Watt. However, due to the fouling of the heat exchangers and the need of the reactor to reach a temperature of 310 degrees Celsius and the temperature conditions at the end of catalyst life due to coke, it was inevitable that worst operating conditions had to be considered. The simulation results showed that heat transfer surface area of heat exchangers must be increased by 24% to achieve the actual operating conditions. Suggestions for compensating the heat transfer surface area, including increasing the number of tube to 1370 branches for each of heat exchangers, Increase length of the tubes to 6400 mm, change the shell structure from type E to F or adding a new heat exchanger similar to the existing system, in series with those, was proposed that latter was considered as a more economical solution.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Zare, A. R., Hosseini, S. M. S., & Kamyabi, M. M.. (2021). Evaluation and Feasibility of Using Heat Exchanger in Kerosene Unit of Persian Gulf Star Oil Refinery for Sour Naphtha Service. IRANIAN CHEMICAL ENGINEERING JOURNAL, 20(117 ), 79-93. SID. https://sid.ir/paper/415993/en

    Vancouver: Copy

    Zare A. R., Hosseini S. M. S., Kamyabi M. M.. Evaluation and Feasibility of Using Heat Exchanger in Kerosene Unit of Persian Gulf Star Oil Refinery for Sour Naphtha Service. IRANIAN CHEMICAL ENGINEERING JOURNAL[Internet]. 2021;20(117 ):79-93. Available from: https://sid.ir/paper/415993/en

    IEEE: Copy

    A. R. Zare, S. M. S. Hosseini, and M. M. Kamyabi, “Evaluation and Feasibility of Using Heat Exchanger in Kerosene Unit of Persian Gulf Star Oil Refinery for Sour Naphtha Service,” IRANIAN CHEMICAL ENGINEERING JOURNAL, vol. 20, no. 117 , pp. 79–93, 2021, [Online]. Available: https://sid.ir/paper/415993/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button