Title

ERROR ANALYSIS IN ACCELEROMETERS CALIBRATION OF MEASUREMENT WHILE DRILLING INSTRUMENT USED IN DIRECTIONAL DRILLING OPERATIONS

Pages

  69-76

Abstract

 The aim of this paper is to analyze the sensor errors in measurement while drilling (MWD) instrument used in DIRECTIONAL DRILLING operations. The MWD consist of three orthogonal accelerometers, three orthogonal magnetometers and one temperature sensor. The system formulation is achieved through the system analysis and functional consideration. The obtained formulation is validated and verified by comparing the results obtained from measurements and simulations. The accelerometers CALIBRATION, to estimate BIAS factors, SCALE FACTORs and non-orthogonal factors of sensors, is done using optimal non-linear Newton Raphson algorithm by considering the high temperature CALIBRATION coefficients. The accuracy of the experimental results, obtained from several measurement while drilling systems in Iranian national oil drilling company shows the effectiveness of the approach.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SEYED MOOSAVI, SEYED MOHSEN, MOAVENI, BIJAN, MOSHIRI, BEHZAD, & ARVAN, MOHAMMAD REZA. (2014). ERROR ANALYSIS IN ACCELEROMETERS CALIBRATION OF MEASUREMENT WHILE DRILLING INSTRUMENT USED IN DIRECTIONAL DRILLING OPERATIONS. MODARES JOURNAL OF ELECTRICAL ENGINEERING, 13(4), 69-76. SID. https://sid.ir/paper/703441/en

    Vancouver: Copy

    SEYED MOOSAVI SEYED MOHSEN, MOAVENI BIJAN, MOSHIRI BEHZAD, ARVAN MOHAMMAD REZA. ERROR ANALYSIS IN ACCELEROMETERS CALIBRATION OF MEASUREMENT WHILE DRILLING INSTRUMENT USED IN DIRECTIONAL DRILLING OPERATIONS. MODARES JOURNAL OF ELECTRICAL ENGINEERING[Internet]. 2014;13(4):69-76. Available from: https://sid.ir/paper/703441/en

    IEEE: Copy

    SEYED MOHSEN SEYED MOOSAVI, BIJAN MOAVENI, BEHZAD MOSHIRI, and MOHAMMAD REZA ARVAN, “ERROR ANALYSIS IN ACCELEROMETERS CALIBRATION OF MEASUREMENT WHILE DRILLING INSTRUMENT USED IN DIRECTIONAL DRILLING OPERATIONS,” MODARES JOURNAL OF ELECTRICAL ENGINEERING, vol. 13, no. 4, pp. 69–76, 2014, [Online]. Available: https://sid.ir/paper/703441/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button