مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

230
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Fault Diagnosis and Fault-Tolerant Control of DFIG Back-ToBack Converter Switch Open-Circuit Based on a New SVM Common-Leg Method with the Application of a Wind Turbine

Pages

  126-138

Abstract

 One of the most common types of Wind Turbines (WTs) is the Doubly-Fed Induction Generator (DFIG) with a Back-to-Back Converter. The power converter with an Insulated Gate Bipolar Transistor (IGBT) switch is essential equipment for power regulation and grid connection in WTs. The converter IGBT open-circuit causes a drawback in output current and as a result, the production performance of the turbine is reduced. Condition Monitoring (CM), Fault Diagnostic (FD), and Fault-Tolerant Control (FTC) of a WT increase the reliability and availability of the turbine and are typical methods to reduce energy production costs and WT downtime. The IGBT switch’ s open-circuit failure rate is significant compared to the overall fault rate in WTs. This paper discusses IGBT open-circuit FTC in back-to-back DFIG converters. In the proposed structure, the converter switch fault is first diagnosed using a fast and numerical method. In the first part, a method based on normalized phase currents, the absolute of the phase currents, and an adaptive threshold is used. The FTC system can be divided into two classes of redundancy and non-redundancy or into active and inactive classes. In this article, the proposed method is active and non-redundancy. In the second step, the FTC process is activated to compensate for the system degradation. In this method, the faulty leg is removed with the gate opening of both IGBTs in one leg by the controller, and one of the legs is positioned as a common leg between the two grid side and rotor side converters. The conventional method in this structure is to use Pulse Width Modulation (PWM) with a zero sequence signal. The novelty of the paper is the use of the proposed SVM vector control. The proposed structure is inexpensive. Furthermore, the fault diagnostic structure operates without additional sensors and the FTC structure operates with minimal hardware. To evaluate the proposed structure, a MW turbine software simulator based on real data is used. The simulations show that the proposed method is effective and robust in FD and FTC and that the proposed method is successful in detecting multiple defects of the grid-side and rotor-side converters, as well as the defects of one leg. The proposed method can compensate for the open switch fault to construct three-phase output currents by comparing the numerical parameters. The ability of the proposed method is specified.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KAMARZARRIN, MEHRNOOSH, REFAN, MOHAMMAD HOSSEIN, & AMIRI, PARVIZ. (2022). Fault Diagnosis and Fault-Tolerant Control of DFIG Back-ToBack Converter Switch Open-Circuit Based on a New SVM Common-Leg Method with the Application of a Wind Turbine. IRANIAN ELECTRIC INDUSTRY JOURNAL OF QUALITY AND PRODUCTIVITY (IEIJQP), 11(1 (26) ), 126-138. SID. https://sid.ir/paper/957429/en

    Vancouver: Copy

    KAMARZARRIN MEHRNOOSH, REFAN MOHAMMAD HOSSEIN, AMIRI PARVIZ. Fault Diagnosis and Fault-Tolerant Control of DFIG Back-ToBack Converter Switch Open-Circuit Based on a New SVM Common-Leg Method with the Application of a Wind Turbine. IRANIAN ELECTRIC INDUSTRY JOURNAL OF QUALITY AND PRODUCTIVITY (IEIJQP)[Internet]. 2022;11(1 (26) ):126-138. Available from: https://sid.ir/paper/957429/en

    IEEE: Copy

    MEHRNOOSH KAMARZARRIN, MOHAMMAD HOSSEIN REFAN, and PARVIZ AMIRI, “Fault Diagnosis and Fault-Tolerant Control of DFIG Back-ToBack Converter Switch Open-Circuit Based on a New SVM Common-Leg Method with the Application of a Wind Turbine,” IRANIAN ELECTRIC INDUSTRY JOURNAL OF QUALITY AND PRODUCTIVITY (IEIJQP), vol. 11, no. 1 (26) , pp. 126–138, 2022, [Online]. Available: https://sid.ir/paper/957429/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button