مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

166
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Validity of RLC Equivalent Circuit of Grounding Electrodes in Combination with Equivalent Resistivity in Two-layer Soils and Its Application in Transient Analysis of Arrester-Connected Overhead Lines under Lightning Strike

Pages

  35-42

Abstract

 In this paper, approximate and exact equivalent circuits for Grounding Electrodes buried in horizontally twolayered soils are introduced. In the approximate one, Two-layer Soil is approximated with equivalent resistivity and then the Grounding Electrode is modelled with RLC equivalent circuit, while in the exact one, the input impedance of the Grounding Electrode is first computed in the frequency domain via numerical solution of Maxwell’ s equations. Then the input impedance is replaced with rational functions and finally the equivalent circuit in time domain is achieved. In order to extract the validity range of the approximate circuit in Two-layer Soils, transient analysis of Overhead Line terminated to Arrester in the presence of Two-layer Soils is carried out where the Grounding Electrodes are modelled with approximate and exact circuits. The simulation results show that when the thickness of the first layer is less than 1 meter or greater than 40 meter, the approximate circuit yields acceptable results. In addition, sensitivity analysis is carried out on the thickness of the first layer with respect to the single-layer soil. The simulation results show that when the thickness is greater than 40 meter, the two-layer and single-layer soils have the same behavior.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MEHRABI, S., & OSTADZADEH, S.R.. (2021). Validity of RLC Equivalent Circuit of Grounding Electrodes in Combination with Equivalent Resistivity in Two-layer Soils and Its Application in Transient Analysis of Arrester-Connected Overhead Lines under Lightning Strike. JOURNAL OF APPLIED ELECTROMAGNETIC, 9(1 (22) ), 35-42. SID. https://sid.ir/paper/960130/en

    Vancouver: Copy

    MEHRABI S., OSTADZADEH S.R.. Validity of RLC Equivalent Circuit of Grounding Electrodes in Combination with Equivalent Resistivity in Two-layer Soils and Its Application in Transient Analysis of Arrester-Connected Overhead Lines under Lightning Strike. JOURNAL OF APPLIED ELECTROMAGNETIC[Internet]. 2021;9(1 (22) ):35-42. Available from: https://sid.ir/paper/960130/en

    IEEE: Copy

    S. MEHRABI, and S.R. OSTADZADEH, “Validity of RLC Equivalent Circuit of Grounding Electrodes in Combination with Equivalent Resistivity in Two-layer Soils and Its Application in Transient Analysis of Arrester-Connected Overhead Lines under Lightning Strike,” JOURNAL OF APPLIED ELECTROMAGNETIC, vol. 9, no. 1 (22) , pp. 35–42, 2021, [Online]. Available: https://sid.ir/paper/960130/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button