مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

178
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A New Modified Hyperbolic S Transform-Based Method for Discrimination of Internal Fault from Other Abnormal Conditions in Power Transformer

Author(s)

Behvandi Abdolreza | Seifossadat Seyed Ghodratollah | Saffarian Alireza | Issue Writer Certificate 

Pages

  1085-1096

Abstract

 In this paper, a new method is presented for discrimination of internal fault other abnormal conditions in power transformers. Since the differential current signals are non-stationary, a powerful tool such as S transform is needed for time-frequency analysis of them. First, by considering the effective factors, different simulations for internal fault, inrush current, external fault, over-excitation and ultrasaturation conditions are performed via PSCAD/EMTDC software in different operating conditions of transformer. Then, the obtained differential current signals are analyzed by modified hyperbolic S transform. Important characteristics are extracted from modified hyperbolic S transform and according to them, different conditions are distinguished and classified. These features include: energy contour of first level, variance index, standard deviation of the fundamental frequency and second harmonic component and three special criteria. The process of modified hyperbolic S transform and performing the proposed algorithm are performed in MATLAB software. In this paper, all of possible transient conditions and effects of the saturation of current transformers are considered. Finally, the accuracy and precision of the proposed method are compared with different methods in conditions with noise and without noise. The results show good performance of the proposed method.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Behvandi, Abdolreza, Seifossadat, Seyed Ghodratollah, & Saffarian, Alireza. (2020). A New Modified Hyperbolic S Transform-Based Method for Discrimination of Internal Fault from Other Abnormal Conditions in Power Transformer. TABRIZ JOURNAL OF ELECTRICAL ENGINEERING, 50(3 (93) ), 1085-1096. SID. https://sid.ir/paper/962474/en

    Vancouver: Copy

    Behvandi Abdolreza, Seifossadat Seyed Ghodratollah, Saffarian Alireza. A New Modified Hyperbolic S Transform-Based Method for Discrimination of Internal Fault from Other Abnormal Conditions in Power Transformer. TABRIZ JOURNAL OF ELECTRICAL ENGINEERING[Internet]. 2020;50(3 (93) ):1085-1096. Available from: https://sid.ir/paper/962474/en

    IEEE: Copy

    Abdolreza Behvandi, Seyed Ghodratollah Seifossadat, and Alireza Saffarian, “A New Modified Hyperbolic S Transform-Based Method for Discrimination of Internal Fault from Other Abnormal Conditions in Power Transformer,” TABRIZ JOURNAL OF ELECTRICAL ENGINEERING, vol. 50, no. 3 (93) , pp. 1085–1096, 2020, [Online]. Available: https://sid.ir/paper/962474/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button