مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

669
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Optimization of reflectance pulse oximeter source-detector space using analytical model of light propagation in heterogeneous tissue to accurate diagnosis of Hypoxia tumoral tissue

Pages

  1-14

Abstract

Pulse oximetry is a very significant method in medical monitoring. Due to the restriction in the use of the transmission pulse oximeter in high-density tissues, this research aims to focus on the study and development of the reflectance pulse oximeters, because it is able to show the blood oxygen saturation level (2SaO) in various densities. To this end, considering the benefits of Photon diffusion theory over Beer-Lambert law, a new mathematical (analytical) method was developed to investigate the inensity reflective Light propagation in a heterogeneous medium such as a fingerprint. Then, using the obtained analytical model, source-detector space was optimized so that by decreasing the sensitivity of the motion effects on light scattering the accuracy rate will increase. To verify the results obtained from the analytical model, Monte Carlo simulation results were used as a standard method compared to experimental data. This comparison showed the agreement of the analytical model with the results of these two methods with minor differences. By using the sensitivity function, the optimum distance of the detector from the light sourcewas obtained 4. 8 mm and 2. 8 mm for red and infrared lights, respectively. An overview of the results suggests that Light propagation characteristics can be accurately assessed through an analytical model.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MEHRABI, M., GHANNADI MARAGHEH, M., & SETAYESHI, S.. (2020). Optimization of reflectance pulse oximeter source-detector space using analytical model of light propagation in heterogeneous tissue to accurate diagnosis of Hypoxia tumoral tissue. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, -(1 (91) ), 1-14. SID. https://sid.ir/paper/97840/en

    Vancouver: Copy

    MEHRABI M., GHANNADI MARAGHEH M., SETAYESHI S.. Optimization of reflectance pulse oximeter source-detector space using analytical model of light propagation in heterogeneous tissue to accurate diagnosis of Hypoxia tumoral tissue. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY[Internet]. 2020;-(1 (91) ):1-14. Available from: https://sid.ir/paper/97840/en

    IEEE: Copy

    M. MEHRABI, M. GHANNADI MARAGHEH, and S. SETAYESHI, “Optimization of reflectance pulse oximeter source-detector space using analytical model of light propagation in heterogeneous tissue to accurate diagnosis of Hypoxia tumoral tissue,” JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, vol. -, no. 1 (91) , pp. 1–14, 2020, [Online]. Available: https://sid.ir/paper/97840/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top