مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

556
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Optimization of Rainwater Storage Tanks for Building (Case Study: Guilan_Rasht)

Pages

  227-241

Abstract

 Rasht is one of the richest cities in rainfall in Iran, and because of collecting rain from the roof of the buildings a considerable amount of water can be stored, then designing and implementing of Rainwater collection systems in Rasht can collect and save a significant amount of Rainwater for usages like: green-space irrigation or Non-drinkable usages as whole. The catchment bank (Rainwater storage bank) is the most important and expensive component of Rainwater Harvesting System (RWH) implementation on the roof of residential buildings. The reliability of these storage banks was estimated between 100% and 82% in three years of wetness, drought and normal index. The demand amount of this research is considered equal to the water needed for the irrigation of the cultivated grass in the green space of each building in the hot seasons. Then, we have estimated the optimum volume of storage bank using mixed integer linear programming method in LINGO. 17 software for each of the buildings considering the expected reliability coefficient of the storage banks (70, 80 and 90%). These volumes are between 1. 18 and 13. 49 cubic meters in three years of wetness, drought and normal index with different reliabilities. Finally, we have estimated the storage bank volume of each demand for one of the roofs in different demands and the results were calculated between 0. 55 and 5. 26 cubic meters.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Nojoumi Siahmard, S., SHAFIEI SABET, B., & JANATROSTAMI, S.. (2020). Optimization of Rainwater Storage Tanks for Building (Case Study: Guilan_Rasht). IRAN-WATER RESOURCES RESEARCH, 15(4 ), 227-241. SID. https://sid.ir/paper/99989/en

    Vancouver: Copy

    Nojoumi Siahmard S., SHAFIEI SABET B., JANATROSTAMI S.. Optimization of Rainwater Storage Tanks for Building (Case Study: Guilan_Rasht). IRAN-WATER RESOURCES RESEARCH[Internet]. 2020;15(4 ):227-241. Available from: https://sid.ir/paper/99989/en

    IEEE: Copy

    S. Nojoumi Siahmard, B. SHAFIEI SABET, and S. JANATROSTAMI, “Optimization of Rainwater Storage Tanks for Building (Case Study: Guilan_Rasht),” IRAN-WATER RESOURCES RESEARCH, vol. 15, no. 4 , pp. 227–241, 2020, [Online]. Available: https://sid.ir/paper/99989/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button