مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

31
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

16
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Polythiophene Imprinted CeO2 Fluorescent Probe for Lead Detection in Tab Water Samples

Pages

  87-96

Abstract

 The development of real-time, highly sensitive, and selective, simple techniques for the detection of toxic Pb2+ in water was challenged. However, in this study, a highly efficient fluorescent probe based on Polythiophene Imprinted CeO2 nanocomposite for selective detection of Pb2+ ion was developed by polymerization method. The developed fluorescent probe was characterized by using powder X-ray diffraction (XRD), Fourier-Transform Infrared spectroscopy (FT-IR), and Scanning Electron Microscope (SEM). Upon binding to the Imprinted binding sites PT/CeO2 the Pb2+ interacts with the molecular orbital and their fluorescence is quenched via reverse photoinduced electron transfer which results in qualitative and quantitative detection. The factor affecting the detection system such as pH and concentration are optimized. Additionally, the PT/CeO2 fluorescent sensor exhibits high sensitivity with a Stern Volmer Quenching (KSV) value of 6. 39 × 103 M-1. The practical application of the sensor was also tested by spiking with different concentrations of Pb2+ ion solutions on tab water samples. The result indicates a good linear relation between FO/F and the spiked concentrations with the coefficient of regression R2 = 0. 99 (n = 3) and also confirms that the found values are agreed well with the spiked amount. The obtained amounts of lead metal ion concentrations in tap water were 15. 39 μ, M which exceeded the allowable limit as stated by WHO.

Multimedia

  • No record.
  • Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Ali, Abdu Hussen. (2023). Polythiophene Imprinted CeO2 Fluorescent Probe for Lead Detection in Tab Water Samples. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 10(1), 87-96. SID. https://sid.ir/paper/1073035/en

    Vancouver: Copy

    Ali Abdu Hussen. Polythiophene Imprinted CeO2 Fluorescent Probe for Lead Detection in Tab Water Samples. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH[Internet]. 2023;10(1):87-96. Available from: https://sid.ir/paper/1073035/en

    IEEE: Copy

    Abdu Hussen Ali, “Polythiophene Imprinted CeO2 Fluorescent Probe for Lead Detection in Tab Water Samples,” ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, vol. 10, no. 1, pp. 87–96, 2023, [Online]. Available: https://sid.ir/paper/1073035/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button