مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

3,682
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

12

Information Journal Paper

Title

DETERMINATION OF LIMIT OF THERMAL COMFORT IN ARID CLIMATE (CASE STUDY: YAZD CITY)

Pages

  39-46

Abstract

 In sustainable development process, native evaluation of limit of THERMAL COMFORT with the goal of energy conservation is necessary in different climates.  Because with determination of these limits, energy loss is declined considerably and causes to decline of unsuitable energy consuming. With respect to, more than 60 percent of Iran area is located in arid and ultra ARID CLIMATE and therefore recognition of limit of THERMAL COMFORT in this climate has multiplied importance.For calculation of limit of THERMAL COMFORT, YAZD city was considered with arid and cold climate as the case study in this research. The limits of THERMAL COMFORT were reformed on the basis of the latitude of the study area. Then the limits of THERMAL COMFORT were calculated for warm and cold terms of the year according to the climatic data and field observation and on the basis of corrected diagram of Olgyay.The obtained results show that thermal limit was assessed for summer condition 21.8o-27o and for winter condition 20.4o-23o and also optimum limit of relative humidity was assessed 18% -53%.The proposed thermal and humidity limits, maintains proper internal conditions, reduces energy unsuitable consumption during of years  

Cites

References

  • No record.
  • Cite

    APA: Copy

    SADEGHI RAVESH, M.H., & TABATABAEI, S.M.. (2009). DETERMINATION OF LIMIT OF THERMAL COMFORT IN ARID CLIMATE (CASE STUDY: YAZD CITY). HOVIATESHAHR, 3(4), 39-46. SID. https://sid.ir/paper/154684/en

    Vancouver: Copy

    SADEGHI RAVESH M.H., TABATABAEI S.M.. DETERMINATION OF LIMIT OF THERMAL COMFORT IN ARID CLIMATE (CASE STUDY: YAZD CITY). HOVIATESHAHR[Internet]. 2009;3(4):39-46. Available from: https://sid.ir/paper/154684/en

    IEEE: Copy

    M.H. SADEGHI RAVESH, and S.M. TABATABAEI, “DETERMINATION OF LIMIT OF THERMAL COMFORT IN ARID CLIMATE (CASE STUDY: YAZD CITY),” HOVIATESHAHR, vol. 3, no. 4, pp. 39–46, 2009, [Online]. Available: https://sid.ir/paper/154684/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops

  • No record.





  • Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button